Glass and polymeric membrane electrodes for the measurement of pH in milk and cheese

Praveen Upreti, Lloyd Metzger, Phil Buhlmann

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70% have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.

Original languageEnglish (US)
Pages (from-to)139-148
Number of pages10
JournalTalanta
Volume63
Issue number1
DOIs
StatePublished - May 10 2004

Fingerprint

Polymeric membranes
Cheeses
Cheese
Glass
Electrodes
Milk
Membranes
Ion-Selective Electrodes
Ionophores
Emulsions
Plasticizers
Monovalent Cations
Food Industry
Ceramics
Caseins
Ether
Electrolytes
Food

Keywords

  • Cheese
  • Dairy products
  • Glass electrode
  • Ion-selective electrode
  • Ionophore
  • Milk
  • pH measurement

Cite this

Glass and polymeric membrane electrodes for the measurement of pH in milk and cheese. / Upreti, Praveen; Metzger, Lloyd; Buhlmann, Phil.

In: Talanta, Vol. 63, No. 1, 10.05.2004, p. 139-148.

Research output: Contribution to journalArticle

@article{9a92a8445e7447799b0b7490e437c8d6,
title = "Glass and polymeric membrane electrodes for the measurement of pH in milk and cheese",
abstract = "While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70{\%} have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.",
keywords = "Cheese, Dairy products, Glass electrode, Ion-selective electrode, Ionophore, Milk, pH measurement",
author = "Praveen Upreti and Lloyd Metzger and Phil Buhlmann",
year = "2004",
month = "5",
day = "10",
doi = "10.1016/j.talanta.2003.12.020",
language = "English (US)",
volume = "63",
pages = "139--148",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Glass and polymeric membrane electrodes for the measurement of pH in milk and cheese

AU - Upreti, Praveen

AU - Metzger, Lloyd

AU - Buhlmann, Phil

PY - 2004/5/10

Y1 - 2004/5/10

N2 - While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70% have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.

AB - While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70% have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.

KW - Cheese

KW - Dairy products

KW - Glass electrode

KW - Ion-selective electrode

KW - Ionophore

KW - Milk

KW - pH measurement

UR - http://www.scopus.com/inward/record.url?scp=1842684439&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1842684439&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2003.12.020

DO - 10.1016/j.talanta.2003.12.020

M3 - Article

VL - 63

SP - 139

EP - 148

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 1

ER -