Gas chromatographic-mass spectrometric determination of benzo[a]pyrene and chrysene diol epoxide globin adducts in humans

Assieh A. Melikian, Sun Peng, Christopher Pierpont, Stuart Coleman, Stephen S. Hecht

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

The efficacy of a newly developed gas chromatography-negative ion chemical ionization-mass spectrometry-selected ion monitoring (GC-NICI-MS- SIM) assay for measuring globin adducts of benzo[a]pyrene (B[a]P) and chrysene diol epoxides in humans was evaluated. In this pilot study, smokers and nonsmokers were selected as exposed and nonexposed groups. Using [2H12]r-7,t-8,9,c-10-tetrahydroxy-7,8,9,10-tetrahydrobenzo[a]pyrene ([2H12]trans, anti-B[a]P-tetraol) as an internal standard, B[a]P-tetraols released from globin after hydrolysis and derivatization were quantified by GC-NICI-MS-SIM. Levels of trans-1,2-dihydroxy-3,4-epoxy-1,2,3,4- tetrahydrochrysene (chrysene-DE)-globin adducts were estimated by assuming that the recovery and the MS response of the perdeuterated B[a]P-tetraol internal standard reflected the recovery and MS response of chrysene tetraols. The assay was found to be reproducible and sensitive enough to detect both analytes in all samples. The mean levels of B[a]P-tetraols released from the corresponding benzo[a]pyrene diol epoxide (BPDE) globin adducts in smokers were significantly higher than those in nonsmokers, i.e., 2.6 ± 0.6 SE fmol/mg globin (ranging from 1.2 to 7.8 fmol/mg globin) in smokers and 0.97 ± 0.05 SE fmol/mg globin (ranging from 0.7 to 1.3 fmol/mg globin) in nonsmokers (P < 0.01). Interestingly, estimated levels of chrysene-DE-globin adducts in the same subjects were about two orders of magnitude higher than those of the globin adducts of BPDE. The mean of the chrysene-DE adducts in smokers was estimated to be 310 ± 30 SE fmol/mg globin (ranging from 190 to 460 fmol/mg globin) and that in nonsmokers was 250 ± 25 SE fmol/mg globin (ranging from 110 to 380 fmol/mg). Although the estimated mean of chrysene-DE adducts with globin in smokers appeared to be about 25% higher than in nonsmokers, the difference was not significant (P = 0.06). The results of this study demonstrate the feasibility of the GC-NICI- MS-SIM method for measurement of BPDE globin adducts in humans.

Original languageEnglish (US)
Pages (from-to)833-839
Number of pages7
JournalCancer Epidemiology Biomarkers and Prevention
Volume6
Issue number10
StatePublished - 1997

Fingerprint Dive into the research topics of 'Gas chromatographic-mass spectrometric determination of benzo[a]pyrene and chrysene diol epoxide globin adducts in humans'. Together they form a unique fingerprint.

Cite this