TY - JOUR
T1 - Functional outcomes and complications of plate fixation for midshaft clavicle fractures by type and location
T2 - a systematic review and meta-analysis
AU - Hornung, Christopher M.
AU - Kramer, Riley
AU - Levine, Joshua
AU - Hannink, Gerjon
AU - Hoogervorst, Paul
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2024/5
Y1 - 2024/5
N2 - Background: Various plate types are used in the surgical treatment of displaced midshaft clavicle fractures. These plates can be positioned in different locations on the clavicle, although no studies to date have elucidated optimal plate type and location of fixation. This systematic review compares the functional outcomes and complications in the management of displaced midshaft clavicle fractures using plate fixation by stratifying by both plate type and location. Methods: A systematic review according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted to identify all papers reporting functional outcomes, union rates, and/or complications using plates for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until March 2022. A meta-analysis was conducted for functional outcomes and type of complication, stratified by plate type (locking, compression, or reconstruction) and location (superior or anteroinferior). Pooled estimates of functional outcome scores and incidence of complications were calculated using a random effects model. Risk of bias and quality were assessed using the risk of bias version 2 and ROBINS-I (Risk Of Bias In Non-randomised Studies - of Interventions) tools. The confidence in estimates were rated and described according to the recommendations of the GRADE (Grading of Recommendations, Assessment, Development, and Evaluations) working group. Results: Forty-five studies were included in the systematic review and 43 were included in the meta-analysis. Depending on plate type and location, pooled Constant-Murley Scores ranged from 89.23 to 93.48 at 12 months. Nonunion rates were 3% (95% confidence interval [CI] 1-6) for superior locking plates (GRADE Low). Rates of any complication (nonunion, hardware failure, hardware irritation, wound dehiscence, keloid, superficial infection, deep infection, delayed union, malunion, and/or persistent pain) by plate type and location ranged from 3% to 17% (GRADE Very Low to Moderate). Superior compression plates had the highest incidence of any complications (17% [95% CI 5-44], GRADE Very Low), while anterior inferior compression plates had the lowest incidence of any complication (3% [95% CI 0-15], GRADE Very Low). Hardware irritation was the most reported individual complication for superior locking plates and superior compression plates, 11% (95% CI 7-17, GRADE Low) and 11% (95% CI 3-33, GRADE Very Low), respectively. Conclusion: Although most studies were of low quality, studies reporting functional outcomes generally showed good functional results and similar incidence of any complication regardless of plate type and location. There is no evidence of a plate and location combination to optimize patient functional outcomes or complications. We were unable to reliably evaluate union rates or individual complications for most plate types stratified by location.
AB - Background: Various plate types are used in the surgical treatment of displaced midshaft clavicle fractures. These plates can be positioned in different locations on the clavicle, although no studies to date have elucidated optimal plate type and location of fixation. This systematic review compares the functional outcomes and complications in the management of displaced midshaft clavicle fractures using plate fixation by stratifying by both plate type and location. Methods: A systematic review according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted to identify all papers reporting functional outcomes, union rates, and/or complications using plates for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until March 2022. A meta-analysis was conducted for functional outcomes and type of complication, stratified by plate type (locking, compression, or reconstruction) and location (superior or anteroinferior). Pooled estimates of functional outcome scores and incidence of complications were calculated using a random effects model. Risk of bias and quality were assessed using the risk of bias version 2 and ROBINS-I (Risk Of Bias In Non-randomised Studies - of Interventions) tools. The confidence in estimates were rated and described according to the recommendations of the GRADE (Grading of Recommendations, Assessment, Development, and Evaluations) working group. Results: Forty-five studies were included in the systematic review and 43 were included in the meta-analysis. Depending on plate type and location, pooled Constant-Murley Scores ranged from 89.23 to 93.48 at 12 months. Nonunion rates were 3% (95% confidence interval [CI] 1-6) for superior locking plates (GRADE Low). Rates of any complication (nonunion, hardware failure, hardware irritation, wound dehiscence, keloid, superficial infection, deep infection, delayed union, malunion, and/or persistent pain) by plate type and location ranged from 3% to 17% (GRADE Very Low to Moderate). Superior compression plates had the highest incidence of any complications (17% [95% CI 5-44], GRADE Very Low), while anterior inferior compression plates had the lowest incidence of any complication (3% [95% CI 0-15], GRADE Very Low). Hardware irritation was the most reported individual complication for superior locking plates and superior compression plates, 11% (95% CI 7-17, GRADE Low) and 11% (95% CI 3-33, GRADE Very Low), respectively. Conclusion: Although most studies were of low quality, studies reporting functional outcomes generally showed good functional results and similar incidence of any complication regardless of plate type and location. There is no evidence of a plate and location combination to optimize patient functional outcomes or complications. We were unable to reliably evaluate union rates or individual complications for most plate types stratified by location.
KW - Compression plate
KW - Level IV
KW - Locking plate
KW - Meta-Analysis
KW - Midshaft clavicle fracture
KW - Plate fixation
KW - Reconstruction plate
KW - Systematic review
UR - http://www.scopus.com/inward/record.url?scp=85188445439&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85188445439&partnerID=8YFLogxK
U2 - 10.1016/j.jseint.2024.01.007
DO - 10.1016/j.jseint.2024.01.007
M3 - Review article
C2 - 38707570
AN - SCOPUS:85188445439
SN - 2468-6026
VL - 8
SP - 407
EP - 422
JO - JSES International
JF - JSES International
IS - 3
ER -