Frequency dependence of regional lung clearance of 133Xe in normal men

R. S. Kronenberg, Douglas Wangensteen, R. A. Ponto

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

We measured the one-half time of 133Xe washout from the whole lung and from 9 horizontal lung regions in 6 normal men during normal breathing and at 50 breaths/min. The diaphragm was located with a contour map prior to the selection of the 9 horizontal regions. Artifacts caused by the tissue solubility of 133Xe were reduced by expressing regional clearance relative to whole lung clearance. During normal breathing there was a progressive increase in the relative clearance of 133Xe from the lung apex to the base when each region was compared to the lung as a whole. At 50 breaths/min, relative clearance increased from the lung apex only for about 18.5 to 20 cm. At that point, the relative clearance rate of the horizontal regions began to fall and at the lung base was slower than that of the whole lung. These results are consistent with the concept that dependent lung regions have longer time constants than regions at the top of the lung.

Original languageEnglish (US)
Pages (from-to)293-303
Number of pages11
JournalRespiration Physiology
Volume27
Issue number3
DOIs
StatePublished - Jan 1 1976

Fingerprint

Lung
Respiration
Diaphragm
Artifacts
Solubility

Keywords

  • Breathing frequency
  • Regional ventilation Pulmonary washout
  • Xenon

Cite this

Frequency dependence of regional lung clearance of 133Xe in normal men. / Kronenberg, R. S.; Wangensteen, Douglas; Ponto, R. A.

In: Respiration Physiology, Vol. 27, No. 3, 01.01.1976, p. 293-303.

Research output: Contribution to journalArticle

Kronenberg, R. S. ; Wangensteen, Douglas ; Ponto, R. A. / Frequency dependence of regional lung clearance of 133Xe in normal men. In: Respiration Physiology. 1976 ; Vol. 27, No. 3. pp. 293-303.
@article{da5c4b2244554178a2bcbce3c3c6da00,
title = "Frequency dependence of regional lung clearance of 133Xe in normal men",
abstract = "We measured the one-half time of 133Xe washout from the whole lung and from 9 horizontal lung regions in 6 normal men during normal breathing and at 50 breaths/min. The diaphragm was located with a contour map prior to the selection of the 9 horizontal regions. Artifacts caused by the tissue solubility of 133Xe were reduced by expressing regional clearance relative to whole lung clearance. During normal breathing there was a progressive increase in the relative clearance of 133Xe from the lung apex to the base when each region was compared to the lung as a whole. At 50 breaths/min, relative clearance increased from the lung apex only for about 18.5 to 20 cm. At that point, the relative clearance rate of the horizontal regions began to fall and at the lung base was slower than that of the whole lung. These results are consistent with the concept that dependent lung regions have longer time constants than regions at the top of the lung.",
keywords = "Breathing frequency, Regional ventilation Pulmonary washout, Xenon",
author = "Kronenberg, {R. S.} and Douglas Wangensteen and Ponto, {R. A.}",
year = "1976",
month = "1",
day = "1",
doi = "10.1016/0034-5687(76)90059-1",
language = "English (US)",
volume = "27",
pages = "293--303",
journal = "Respiratory Physiology and Neurobiology",
issn = "1569-9048",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - Frequency dependence of regional lung clearance of 133Xe in normal men

AU - Kronenberg, R. S.

AU - Wangensteen, Douglas

AU - Ponto, R. A.

PY - 1976/1/1

Y1 - 1976/1/1

N2 - We measured the one-half time of 133Xe washout from the whole lung and from 9 horizontal lung regions in 6 normal men during normal breathing and at 50 breaths/min. The diaphragm was located with a contour map prior to the selection of the 9 horizontal regions. Artifacts caused by the tissue solubility of 133Xe were reduced by expressing regional clearance relative to whole lung clearance. During normal breathing there was a progressive increase in the relative clearance of 133Xe from the lung apex to the base when each region was compared to the lung as a whole. At 50 breaths/min, relative clearance increased from the lung apex only for about 18.5 to 20 cm. At that point, the relative clearance rate of the horizontal regions began to fall and at the lung base was slower than that of the whole lung. These results are consistent with the concept that dependent lung regions have longer time constants than regions at the top of the lung.

AB - We measured the one-half time of 133Xe washout from the whole lung and from 9 horizontal lung regions in 6 normal men during normal breathing and at 50 breaths/min. The diaphragm was located with a contour map prior to the selection of the 9 horizontal regions. Artifacts caused by the tissue solubility of 133Xe were reduced by expressing regional clearance relative to whole lung clearance. During normal breathing there was a progressive increase in the relative clearance of 133Xe from the lung apex to the base when each region was compared to the lung as a whole. At 50 breaths/min, relative clearance increased from the lung apex only for about 18.5 to 20 cm. At that point, the relative clearance rate of the horizontal regions began to fall and at the lung base was slower than that of the whole lung. These results are consistent with the concept that dependent lung regions have longer time constants than regions at the top of the lung.

KW - Breathing frequency

KW - Regional ventilation Pulmonary washout

KW - Xenon

UR - http://www.scopus.com/inward/record.url?scp=0017151473&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017151473&partnerID=8YFLogxK

U2 - 10.1016/0034-5687(76)90059-1

DO - 10.1016/0034-5687(76)90059-1

M3 - Article

VL - 27

SP - 293

EP - 303

JO - Respiratory Physiology and Neurobiology

JF - Respiratory Physiology and Neurobiology

SN - 1569-9048

IS - 3

ER -