Field dependence study of in vivo brain 31P MRS up to 16.4T

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

In vivo 31P MRS provides a unique tool for studying bioenergetics of living organs. Although its utility has been limited by the relatively low 31P NMR sensitivity, increasing magnetic field strength (B0) could significantly improve the quality and reliability of the 31P MR spectra for biomedical research. To quantitatively understand the field dependence of in vivo 31P MRS for brain applications, 31P NMR sensitivity of phosphocreatine (PCr) in rat brains was measured and compared at 9.4T and 16.4T. Additionally, the linewidths and T1 relaxation times of PCr and adenosine triphosphate (ATP) resonances obtained from human and animal brains over a wide B0 range from 4T, 7T, and 9.4T to 16.4T were examined and their field dependences were quantified. The results indicate an approximate 1.74-fold 31P signal-to-noise ratio (SNR) gain for PCr at 16.4T compared with 9.4T. An approximate power 1.4 dependence of 31P SNR on B0 was concluded. Substantial improvements in spectral resolution and significantly shortened T1 values of brain PCr and ATP were observed at high/ultrahigh fields, contributing to an additional sensitivity gain and spectral improvement. In summary, the overall findings from this study suggest that in vivo 31P MRS should greatly benefit from high/ultrahigh fields for noninvasive assessment of altered bioenergetics and metabolic processes associated with brain function and neurological diseases.

Original languageEnglish (US)
Pages (from-to)1135-1141
Number of pages7
JournalNMR in biomedicine
Volume27
Issue number9
DOIs
StatePublished - Sep 2014

Fingerprint

Phosphocreatine
Brain
Signal-To-Noise Ratio
Energy Metabolism
Signal to noise ratio
Adenosine Triphosphate
Nuclear magnetic resonance
Spectral resolution
Magnetic Fields
Linewidth
Relaxation time
Biomedical Research
Rats
Animals
Magnetic fields

Keywords

  • High/ultrahigh field
  • Linewidth
  • NMR sensitivity
  • Relaxation time

Cite this

Field dependence study of in vivo brain 31P MRS up to 16.4T. / Lu, Ming; Chen, Wei; Zhu, Xiao Hong.

In: NMR in biomedicine, Vol. 27, No. 9, 09.2014, p. 1135-1141.

Research output: Contribution to journalArticle

@article{7c4f67cda9784bf08aab176313df3c34,
title = "Field dependence study of in vivo brain 31P MRS up to 16.4T",
abstract = "In vivo 31P MRS provides a unique tool for studying bioenergetics of living organs. Although its utility has been limited by the relatively low 31P NMR sensitivity, increasing magnetic field strength (B0) could significantly improve the quality and reliability of the 31P MR spectra for biomedical research. To quantitatively understand the field dependence of in vivo 31P MRS for brain applications, 31P NMR sensitivity of phosphocreatine (PCr) in rat brains was measured and compared at 9.4T and 16.4T. Additionally, the linewidths and T1 relaxation times of PCr and adenosine triphosphate (ATP) resonances obtained from human and animal brains over a wide B0 range from 4T, 7T, and 9.4T to 16.4T were examined and their field dependences were quantified. The results indicate an approximate 1.74-fold 31P signal-to-noise ratio (SNR) gain for PCr at 16.4T compared with 9.4T. An approximate power 1.4 dependence of 31P SNR on B0 was concluded. Substantial improvements in spectral resolution and significantly shortened T1 values of brain PCr and ATP were observed at high/ultrahigh fields, contributing to an additional sensitivity gain and spectral improvement. In summary, the overall findings from this study suggest that in vivo 31P MRS should greatly benefit from high/ultrahigh fields for noninvasive assessment of altered bioenergetics and metabolic processes associated with brain function and neurological diseases.",
keywords = "High/ultrahigh field, Linewidth, NMR sensitivity, Relaxation time",
author = "Ming Lu and Wei Chen and Zhu, {Xiao Hong}",
year = "2014",
month = "9",
doi = "10.1002/nbm.3167",
language = "English (US)",
volume = "27",
pages = "1135--1141",
journal = "NMR in Biomedicine",
issn = "0952-3480",
publisher = "John Wiley and Sons Ltd",
number = "9",

}

TY - JOUR

T1 - Field dependence study of in vivo brain 31P MRS up to 16.4T

AU - Lu, Ming

AU - Chen, Wei

AU - Zhu, Xiao Hong

PY - 2014/9

Y1 - 2014/9

N2 - In vivo 31P MRS provides a unique tool for studying bioenergetics of living organs. Although its utility has been limited by the relatively low 31P NMR sensitivity, increasing magnetic field strength (B0) could significantly improve the quality and reliability of the 31P MR spectra for biomedical research. To quantitatively understand the field dependence of in vivo 31P MRS for brain applications, 31P NMR sensitivity of phosphocreatine (PCr) in rat brains was measured and compared at 9.4T and 16.4T. Additionally, the linewidths and T1 relaxation times of PCr and adenosine triphosphate (ATP) resonances obtained from human and animal brains over a wide B0 range from 4T, 7T, and 9.4T to 16.4T were examined and their field dependences were quantified. The results indicate an approximate 1.74-fold 31P signal-to-noise ratio (SNR) gain for PCr at 16.4T compared with 9.4T. An approximate power 1.4 dependence of 31P SNR on B0 was concluded. Substantial improvements in spectral resolution and significantly shortened T1 values of brain PCr and ATP were observed at high/ultrahigh fields, contributing to an additional sensitivity gain and spectral improvement. In summary, the overall findings from this study suggest that in vivo 31P MRS should greatly benefit from high/ultrahigh fields for noninvasive assessment of altered bioenergetics and metabolic processes associated with brain function and neurological diseases.

AB - In vivo 31P MRS provides a unique tool for studying bioenergetics of living organs. Although its utility has been limited by the relatively low 31P NMR sensitivity, increasing magnetic field strength (B0) could significantly improve the quality and reliability of the 31P MR spectra for biomedical research. To quantitatively understand the field dependence of in vivo 31P MRS for brain applications, 31P NMR sensitivity of phosphocreatine (PCr) in rat brains was measured and compared at 9.4T and 16.4T. Additionally, the linewidths and T1 relaxation times of PCr and adenosine triphosphate (ATP) resonances obtained from human and animal brains over a wide B0 range from 4T, 7T, and 9.4T to 16.4T were examined and their field dependences were quantified. The results indicate an approximate 1.74-fold 31P signal-to-noise ratio (SNR) gain for PCr at 16.4T compared with 9.4T. An approximate power 1.4 dependence of 31P SNR on B0 was concluded. Substantial improvements in spectral resolution and significantly shortened T1 values of brain PCr and ATP were observed at high/ultrahigh fields, contributing to an additional sensitivity gain and spectral improvement. In summary, the overall findings from this study suggest that in vivo 31P MRS should greatly benefit from high/ultrahigh fields for noninvasive assessment of altered bioenergetics and metabolic processes associated with brain function and neurological diseases.

KW - High/ultrahigh field

KW - Linewidth

KW - NMR sensitivity

KW - Relaxation time

UR - http://www.scopus.com/inward/record.url?scp=84905899776&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84905899776&partnerID=8YFLogxK

U2 - 10.1002/nbm.3167

DO - 10.1002/nbm.3167

M3 - Article

C2 - 25070004

AN - SCOPUS:84905899776

VL - 27

SP - 1135

EP - 1141

JO - NMR in Biomedicine

JF - NMR in Biomedicine

SN - 0952-3480

IS - 9

ER -