Extubation readiness in preterm infants: Evaluating the role of monitoring intermittent hypoxemia

  • Elie G. Abu Jawdeh
  • , Amrita Pant
  • , Aayush Gabrani
  • , M. Douglas Cunningham
  • , Thomas M. Raffay
  • , Philip M. Westgate

Research output: Contribution to journal › Article › peer-review

Abstract

Preterm infants with respiratory distress may require mechanical ventilation which is associated with increased pulmonary morbidities. Prompt and successful extubation to noninvasive support is a pressing goal. In this communication, we show original data that increased recurring intermittent hypoxemia (IH, oxygen saturation <80%) may be associated with extubation failure at 72 h in a cohort of neonates <30 weeks gestational age. Current-generation bedside high-resolution pulse oximeters provide saturation profiles that may be of use in identifying extubation readiness and failure. A larger prospective study that utilizes intermittent hypoxemia as an adjunct predictor for extubation readiness is warranted.

Original languageEnglish (US)
Article number237
JournalChildren
Volume8
Issue number3
DOIs
StatePublished - Mar 2021
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Keywords

  • Extubation
  • Intermittent hypoxemia
  • Intubation
  • Preterm
  • Respiratory distress

Fingerprint

Dive into the research topics of 'Extubation readiness in preterm infants: Evaluating the role of monitoring intermittent hypoxemia'. Together they form a unique fingerprint.

Cite this