Abstract
Experiments with both conventional sheet-with-tube and waffled-plate collectors operating with R-113 in a boiling, thermal siphon loop provide insight into the role of collector geometry on boiling performance. Comparison of thermal performance of two collectors shows that a larger ratio of wetted area to total collector area improves performance. Efficiency may be expressed as a linear function of saturation temperature. Comparison of boiling collector system performance to performance of a conventional indirect hot water system indicates that the primary advantage of a boiling collector is the reduction in parasitic power. This comparison is however, biased by the fact that collector design is not optimized in terms of thermal efficiency for boiling operation.
| Original language | English (US) |
|---|---|
| Title of host publication | Solar Engineering |
| Publisher | Publ by ASME |
| Pages | 75-79 |
| Number of pages | 5 |
| ISBN (Print) | 0791809536 |
| State | Published - Jan 1 1993 |
| Event | ASME International Solar Energy Conference - Washington, DC, USA Duration: Apr 4 1993 → Apr 9 1993 |
Other
| Other | ASME International Solar Energy Conference |
|---|---|
| City | Washington, DC, USA |
| Period | 4/4/93 → 4/9/93 |
Fingerprint
Dive into the research topics of 'Experimental study of boiling collectors in thermal siphon operation'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS