@inbook{048baddd69eb4db699c94aa95d21db25,
title = "Experimental studies of boiling performance in curved channels with a two-phase approach flow",
abstract = "Experimental studies on flow boiling heat transfer were performed on a small heater surface using FC-72. Two channel geometries were compared; a straight channel and a curve channel with the heated patch on the concave wall at 90° of bend location. At a given flow velocity and subcooling, critical heat flux is higher in the curved flow than in the straight flow with a difference which grows as saturation conditions are approached.",
author = "Desta, {G. G.} and Simon, {Terrence W}",
year = "1995",
language = "English (US)",
series = "American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD",
number = "12",
editor = "F.B. Cheung and Y.A. Hassan and A. Singh",
booktitle = "Falling Films",
edition = "12",
note = "Proceedings of the 1995 30th National Heat Transfer Conference. Part 14 ; Conference date: 06-08-1995 Through 08-08-1995",
}