TY - JOUR
T1 - Experimental determination of the BOLD field strength dependence in vessels and tissue
AU - Gati, Joseph S.
AU - Menon, Ravi S.
AU - Uǧurbil, Kâmil
AU - Rutt, Brian K.
N1 - Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 1997/8
Y1 - 1997/8
N2 - High resolution functional MRI (fMRI) experiments were performed in human visual cortex at 0.5, 1.5, and 4 T to determine the blood oxygenation level dependent (BOLD) field strength response within regions of obvious venous vessels and cortical gray matter ('tissue'). T2*-weighted FLASH images were collected in single- and multi-echo mode and used to determine the intrinsio BOLD parameters, namely, signal-to-noise ratio (Ψ), the apparent transverse relaxation rate (R2*) and the change in R2* (ΔR2*) between the activated and baseline states. The authors find the average percentage signal change (ΔS/S, measured at TE = T2*) to be large in vessels (13.3 ± 2.3%, 18.4 ± 4.0%, and 15.1 ± 1.2%) compared with that in tissue (1.4 ± 0.7%, 1.9 ± 0.7%, and 3.3 ± 0.2%) at 0.5, 1.5, and 4 T, respectively. The signal-to-noise ratio in optimized, fully relaxed proton density weighted gradient echo images was found to increase linearly with respect to the static magnetic field strength (B0). The predicted upper bound on BOLD contrast-to-noise ratio (ΔS/R)(max) as a function of field strength was calculated and found to behave less than linearly in voxels containing vessels larger than the voxel itself and greater than linearly in voxels containing a mixture of capillaries and veins/venules with a diameter less than that of the voxel.
AB - High resolution functional MRI (fMRI) experiments were performed in human visual cortex at 0.5, 1.5, and 4 T to determine the blood oxygenation level dependent (BOLD) field strength response within regions of obvious venous vessels and cortical gray matter ('tissue'). T2*-weighted FLASH images were collected in single- and multi-echo mode and used to determine the intrinsio BOLD parameters, namely, signal-to-noise ratio (Ψ), the apparent transverse relaxation rate (R2*) and the change in R2* (ΔR2*) between the activated and baseline states. The authors find the average percentage signal change (ΔS/S, measured at TE = T2*) to be large in vessels (13.3 ± 2.3%, 18.4 ± 4.0%, and 15.1 ± 1.2%) compared with that in tissue (1.4 ± 0.7%, 1.9 ± 0.7%, and 3.3 ± 0.2%) at 0.5, 1.5, and 4 T, respectively. The signal-to-noise ratio in optimized, fully relaxed proton density weighted gradient echo images was found to increase linearly with respect to the static magnetic field strength (B0). The predicted upper bound on BOLD contrast-to-noise ratio (ΔS/R)(max) as a function of field strength was calculated and found to behave less than linearly in voxels containing vessels larger than the voxel itself and greater than linearly in voxels containing a mixture of capillaries and veins/venules with a diameter less than that of the voxel.
KW - BOLD
KW - Cortical gray matter
KW - Field strength
KW - Venous vessels
UR - http://www.scopus.com/inward/record.url?scp=0030753056&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030753056&partnerID=8YFLogxK
U2 - 10.1002/mrm.1910380220
DO - 10.1002/mrm.1910380220
M3 - Article
C2 - 9256111
AN - SCOPUS:0030753056
SN - 0740-3194
VL - 38
SP - 296
EP - 302
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 2
ER -