TY - JOUR
T1 - Evaluation of the use of subcutaneous implantable vascular access ports in feline blood donors
AU - Morrison, Jo Ann
AU - Lauer, Susanne K.
AU - Baldwin, Claudia J.
AU - Evans, Richard B.
AU - Andreasen, Claire B.
AU - Kinyon, Joanne M.
AU - Swanson, Elizabeth
PY - 2007/3/15
Y1 - 2007/3/15
N2 - Objective-To compare the ease and effects of collecting blood from cats by use of subcutaneous totally implantable vascular access ports (VAPs) with collection via conventional jugular phlebotomy. Design-Prospective randomized experimental study. Animals-8 healthy cats. Procedures-Cats in the port group (n = 4) underwent monthly blood donation by use of VAPs and manual restraint, and cats in the nonport group (4) underwent monthly blood donation by use of conventional jugular phlebotomy and sedation, for 6 months. Results-Postsurgical VAP-related complications developed in 3 cats and included port erosion (n = 1), disconnection of the port from the catheter (1), and seroma formation (1). Blood was successfully collected 24 of 24 and 20 of 20 times in the nonport and port groups, respectively. Results of bacterial culture of blood were negative in 22 of 24 and 15 of 20 nonport and port collections, respectively. No differences in RBC morphology were observed between groups. Mean blood collection and total donation times were significantly longer for the nonport group. Collection time was more variable in the nonport group, and cats were less tolerant of handling during venipuncture, compared with cats in the port group. Blood collection required a mean of 2.4 persons for the nonport group and 2.1 persons for the port group. Conclusions and Clinical Relevance-Positive results for blood collections via VAPs were increased donor acceptance, decreased number of personnel required, and decreased collection time. Drawbacks included contamination of blood products and port-related complications.
AB - Objective-To compare the ease and effects of collecting blood from cats by use of subcutaneous totally implantable vascular access ports (VAPs) with collection via conventional jugular phlebotomy. Design-Prospective randomized experimental study. Animals-8 healthy cats. Procedures-Cats in the port group (n = 4) underwent monthly blood donation by use of VAPs and manual restraint, and cats in the nonport group (4) underwent monthly blood donation by use of conventional jugular phlebotomy and sedation, for 6 months. Results-Postsurgical VAP-related complications developed in 3 cats and included port erosion (n = 1), disconnection of the port from the catheter (1), and seroma formation (1). Blood was successfully collected 24 of 24 and 20 of 20 times in the nonport and port groups, respectively. Results of bacterial culture of blood were negative in 22 of 24 and 15 of 20 nonport and port collections, respectively. No differences in RBC morphology were observed between groups. Mean blood collection and total donation times were significantly longer for the nonport group. Collection time was more variable in the nonport group, and cats were less tolerant of handling during venipuncture, compared with cats in the port group. Blood collection required a mean of 2.4 persons for the nonport group and 2.1 persons for the port group. Conclusions and Clinical Relevance-Positive results for blood collections via VAPs were increased donor acceptance, decreased number of personnel required, and decreased collection time. Drawbacks included contamination of blood products and port-related complications.
UR - http://www.scopus.com/inward/record.url?scp=33947356148&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33947356148&partnerID=8YFLogxK
U2 - 10.2460/javma.230.6.855
DO - 10.2460/javma.230.6.855
M3 - Article
C2 - 17362159
AN - SCOPUS:33947356148
SN - 0003-1488
VL - 230
SP - 855
EP - 861
JO - Journal of the American Veterinary Medical Association
JF - Journal of the American Veterinary Medical Association
IS - 6
ER -