TY - JOUR
T1 - Evaluation of abdominal aortic aneurysm after endoluminal treatment
T2 - Comparison of color Doppler sonography with biphasic helical CT
AU - Golzarian, Jafar
AU - Murgo, Salvatore
AU - Dussaussois, Luc
AU - Guyot, Sophie
AU - Said, Kamel Ait
AU - Wautrecht, Jean Claude
AU - Struyven, Julien
PY - 2002
Y1 - 2002
N2 - OBJECTIVE. The purpose of this study is to compare color Doppler sonography with biphasic helical CT in the evaluation of abdominal aortic aneurysms after endovascular repair. MATERIALS AND METHODS. Fifty-five patients prospectively underwent both color Doppler sonography and helical CT within 7 days after treatment by endovascular stent-graft. Aneurysmal thrombosis, the patency of the grafts, and the presence of a leak were evaluated in all patients. When a perigraft leak was observed, an attempt was made to identify its origin and outflow vessels. Helical CT was considered the gold standard technique. RESULTS. Helical CT revealed aneurysmal thrombosis in 33 patients and a perigraft leak in 22 patients. In five patients, helical CT detected a small perigraft leak not shown by color Doppler sonography. In three patients with suboptimal examinations, color Doppler sonography revealed a suspected perigraft leak that was not confirmed by helical CT. In these eight patients, the perigraft leak was sealed or no longer observed during follow-up. Compared with enhanced helical CT, the sensitivity and specificity of color Doppler sonography for the diagnosis of a perigraft leak were 77% and 90%, respectively. In seven other patients, helical CT was superior to color Doppler sonography in detecting the origin of the perigraft leak and the outflow vessels. Two iliac artery dissections and one distal migration of the prosthesis were revealed only by helical CT. CONCLUSION. Although color Doppler sonography may detect substantial perigraft leaks, helical CT is superior for detecting the origin of the perigraft leak, the outflow vessels, and the detection of complications related to the procedure.
AB - OBJECTIVE. The purpose of this study is to compare color Doppler sonography with biphasic helical CT in the evaluation of abdominal aortic aneurysms after endovascular repair. MATERIALS AND METHODS. Fifty-five patients prospectively underwent both color Doppler sonography and helical CT within 7 days after treatment by endovascular stent-graft. Aneurysmal thrombosis, the patency of the grafts, and the presence of a leak were evaluated in all patients. When a perigraft leak was observed, an attempt was made to identify its origin and outflow vessels. Helical CT was considered the gold standard technique. RESULTS. Helical CT revealed aneurysmal thrombosis in 33 patients and a perigraft leak in 22 patients. In five patients, helical CT detected a small perigraft leak not shown by color Doppler sonography. In three patients with suboptimal examinations, color Doppler sonography revealed a suspected perigraft leak that was not confirmed by helical CT. In these eight patients, the perigraft leak was sealed or no longer observed during follow-up. Compared with enhanced helical CT, the sensitivity and specificity of color Doppler sonography for the diagnosis of a perigraft leak were 77% and 90%, respectively. In seven other patients, helical CT was superior to color Doppler sonography in detecting the origin of the perigraft leak and the outflow vessels. Two iliac artery dissections and one distal migration of the prosthesis were revealed only by helical CT. CONCLUSION. Although color Doppler sonography may detect substantial perigraft leaks, helical CT is superior for detecting the origin of the perigraft leak, the outflow vessels, and the detection of complications related to the procedure.
UR - http://www.scopus.com/inward/record.url?scp=0036182773&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036182773&partnerID=8YFLogxK
U2 - 10.2214/ajr.178.3.1780623
DO - 10.2214/ajr.178.3.1780623
M3 - Article
C2 - 11856687
AN - SCOPUS:0036182773
SN - 0361-803X
VL - 178
SP - 623
EP - 628
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 3
ER -