Abstract
Background: It remains unclear if percutaneous left ventricular assist device (pLVAD) reduces post-cardiac arrest myocardial dysfunction. Methods: This is a prespecified analysis of a subset of swine that achieved return of spontaneous circulation (ROSC) in a study comparing pLVAD, transient aortic occlusion (AO), or both during cardiopulmonary resuscitation (CPR). Devices were initiated after 24 minutes of ventricular fibrillation cardiac arrest (8 min no-flow and 16 min mechanical CPR). AO was discontinued post-ROSC, and pLVAD support or standard care were continued. Beginning 60 minutes post-ROSC, pLVAD support was weaned to < 1.0 L/min and subsequently removed at 240 minutes. The primary outcome was cardiac index (CI), stroke volume index (SVI), and left ventricular ejection fraction (LVEF) at 240 minutes post-ROSC. Data are shown as mean (standard error). Results: Seventeen swine achieved ROSC without complication and were included in this analysis (pLVAD group, n = 11 and standard care group, n = 6). For the primary outcomes, the pLVAD group had significantly higher CI of 4.2(0.3) vs. 3.1(0.4) L/min/m2 (p = 0.043) and LVEF 60(3) vs. 49(4) % (p = 0.029) at 240 minutes after ROSC when compared with the standard care group, while SVI was not statistically significantly different (32[3] vs. 23[4] mL/min/m2, p = 0.054). During the first 60 minutes post-ROSC, the pLVAD group had significantly higher coronary perfusion pressure, lower LV stroke work index, and total pulmonary resistance index. Conclusion: These results suggest that early pLVAD support after ROSC is associated with better recovery myocardial function compared to standard care after prolonged cardiac arrest.
| Original language | English (US) |
|---|---|
| Article number | 110010 |
| Journal | Resuscitation |
| Volume | 193 |
| DOIs | |
| State | Published - Dec 2023 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2023 Elsevier B.V.
Keywords
- Aortic balloon occlusion
- Cardiac arrest
- Percutaneous ventricular assisted device
- Prolonged cardiac arrest