TY - JOUR
T1 - Dissolved oxygen measurements in aquatic environments
T2 - The effects of changing temperature and pressure on three sensor technologies
AU - Markfort, Corey D.
AU - Hondzo, Miki
PY - 2009/7
Y1 - 2009/7
N2 - Dissolved oxygen (DO) is probably the most important parameter related to water quality and biological habitat in aquatic environments. In situ DO sensors are some of the most valuable tools used by scientists and engineers for the evaluation of water quality in aquatic ecosystems. Presently, we cannot accurately measure DO concentrations under variable temperature and pressure conditions. Pressure and temperature influence polarographic and optical type DO sensors compared to the standard Winkler titration method. Th is study combines laboratory and fi eld experiments to compare and quantify the accuracy and performance of commercially available macro and micro Clark-type oxygen sensors as well as optical sensing technology to the Winkler method under changing pressure and temperature conditions. Field measurements at various lake depths revealed sensor response time up to 11 min due to changes in water temperature, pressure, and DO concentration. Investigators should account for transient response in DO sensors before measurements are collected at a given location. We have developed an eff ective model to predict the transient response time for Clark-type oxygen sensors. The proposed procedure increases the accuracy of DO data collected in situ for profiling applications.
AB - Dissolved oxygen (DO) is probably the most important parameter related to water quality and biological habitat in aquatic environments. In situ DO sensors are some of the most valuable tools used by scientists and engineers for the evaluation of water quality in aquatic ecosystems. Presently, we cannot accurately measure DO concentrations under variable temperature and pressure conditions. Pressure and temperature influence polarographic and optical type DO sensors compared to the standard Winkler titration method. Th is study combines laboratory and fi eld experiments to compare and quantify the accuracy and performance of commercially available macro and micro Clark-type oxygen sensors as well as optical sensing technology to the Winkler method under changing pressure and temperature conditions. Field measurements at various lake depths revealed sensor response time up to 11 min due to changes in water temperature, pressure, and DO concentration. Investigators should account for transient response in DO sensors before measurements are collected at a given location. We have developed an eff ective model to predict the transient response time for Clark-type oxygen sensors. The proposed procedure increases the accuracy of DO data collected in situ for profiling applications.
UR - http://www.scopus.com/inward/record.url?scp=67650503480&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67650503480&partnerID=8YFLogxK
U2 - 10.2134/jeq2008.0197
DO - 10.2134/jeq2008.0197
M3 - Article
C2 - 19549954
AN - SCOPUS:67650503480
SN - 0047-2425
VL - 38
SP - 1766
EP - 1774
JO - Journal of Environmental Quality
JF - Journal of Environmental Quality
IS - 4
ER -