Disparity between indications for and utilization of implantable cardioverter defibrillators in asian patients with heart failure

Yvonne May Fen Chia, Tiew Hwa Katherine Teng, Eugene S.J. Tan, Wan Ting Tay, A. Mark Richards, Calvin Woon Loong Chin, Wataru Shimizu, Sang Weon Park, Chung Lieh Hung, Lieng H. Ling, Tachapong Ngarmukos, Razali Omar, Bambang B. Siswanto, Calambur Narasimhan, Eugene B. Reyes, Cheuk Man Yu, Inder Anand, Michael R. MacDonald, Jonathan Yap, Shu ZhangEric A. Finkelstein, Carolyn S.P. Lam

Research output: Contribution to journalArticle

12 Scopus citations

Abstract

Background-Implantable cardioverter defibrillators (ICDs) are lifesaving devices for patients with heart failure (HF) and reduced ejection fraction. However, utilization and determinants of ICD insertion in Asia are poorly defined. We determined the utilization, associations of ICD uptake, patient-perceived barriers to device therapy and, impact of ICDs on mortality in Asian patients with HF. Methods and Results-Using the prospective ASIAN-HF (Asian Sudden Cardiac Death in Heart Failure) registry, 5276 patients with symptomatic HF and reduced ejection fraction (HFrEF) from 11 Asian regions and across 3 income regions (high: Hong Kong, Japan, Korea, Singapore, and Taiwan; middle: China, Malaysia, and Thailand; and low: India, Indonesia, and Philippines) were studied. ICD utilization, clinical characteristics, as well as device perception and knowledge, were assessed at baseline among ICD-eligible patients (EF ≤35% and New York Heart Association Class IIIII). Patients were followed for the primary outcome of all-cause mortality. Among 3240 ICD-eligible patients (mean age 58.9±12.9 years, 79.1% men), 389 (12%) were ICD recipients. Utilization varied across Asia (from 1.5% in Indonesia to 52.5% in Japan) with a trend toward greater uptake in regions with government reimbursement for ICDs and lower out-ofpocket healthcare expenditure. ICD (versus non-ICD) recipients were more likely to be older (63±11 versus 58±13 year; P<0.001), have tertiary (versus ≤primary) education (34.9% versus 18.1%; P<0.001) and be residing in a high (versus low) income region (64.5% versus 36.5%; P<0.001). Among 2000 ICD nonrecipients surveyed, 55% were either unaware of the benefits of, or needed more information on, device therapy. ICD implantation reduced risks of all-cause mortality (hazard ratio, 0.71; 95% confidence interval, 0.52-0.97) and sudden cardiac deaths (hazard ratio, 0.33; 95% confidence interval, 0.14-0.79) over a median follow-up of 417 days. Conclusions-ICDs reduce mortality risk, yet utilization in Asia is low; with disparity across geographic regions and socioeconomic status. Better patient education and targeted healthcare reforms in extending ICD reimbursement may improve access.

Original languageEnglish (US)
Article numbere003651
JournalCirculation: Cardiovascular Quality and Outcomes
Volume10
Issue number11
DOIs
StatePublished - Jan 1 2017

Keywords

  • Geography
  • Government
  • Heart failure
  • Morbidity
  • Risk

Fingerprint Dive into the research topics of 'Disparity between indications for and utilization of implantable cardioverter defibrillators in asian patients with heart failure'. Together they form a unique fingerprint.

  • Cite this

    Chia, Y. M. F., Teng, T. H. K., Tan, E. S. J., Tay, W. T., Richards, A. M., Chin, C. W. L., Shimizu, W., Park, S. W., Hung, C. L., Ling, L. H., Ngarmukos, T., Omar, R., Siswanto, B. B., Narasimhan, C., Reyes, E. B., Yu, C. M., Anand, I., MacDonald, M. R., Yap, J., ... Lam, C. S. P. (2017). Disparity between indications for and utilization of implantable cardioverter defibrillators in asian patients with heart failure. Circulation: Cardiovascular Quality and Outcomes, 10(11), [e003651]. https://doi.org/10.1161/CIRCOUTCOMES.116.003651