T1 - Disinfection of acrylic denture resin polymer with Rose Bengal, Methylene blue and Porphyrin derivative in photodynamic therapy
AU - Alhenaki, Aasem M.
AU - Alqarawi, Firas K.
AU - Tanveer, Syeda A.
AU - Alshahrani, Faris A.
AU - Alshahrani, Abdullah
AU - AlHamdan, Eman M.
AU - Alzahrani, Khaled M.
AU - Aldahiyan, Nada
AU - Naseem, Mustafa
AU - Vohra, Fahim
AU - Abduljabbar, Tariq
N1 - Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2021/9
Y1 - 2021/9
N2 - Aim: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. Material and Methods: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans Results: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04±0.07 CFU/mL, C. albicans; 2.09±0.85 CFU/mL, S aureus; 3.04±0.11 CFU/mL, and S. mutans; 2.54±0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 µm. Whereas, CFU/mL (log10) values of S.aureus; 3.62±0.68 and S.mutans; 3.41±0.13 plummeted (p<0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16±0.34 and 2.04±0.07 CFU/mL (log10) (p<0.05). Conclusion: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.
AB - Aim: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. Material and Methods: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans Results: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04±0.07 CFU/mL, C. albicans; 2.09±0.85 CFU/mL, S aureus; 3.04±0.11 CFU/mL, and S. mutans; 2.54±0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 µm. Whereas, CFU/mL (log10) values of S.aureus; 3.62±0.68 and S.mutans; 3.41±0.13 plummeted (p<0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16±0.34 and 2.04±0.07 CFU/mL (log10) (p<0.05). Conclusion: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.
KW - Antimicrobial photodynamic therapy
KW - Denture
KW - Methylene blue
KW - Porphyrin derivative
KW - Rose Bengal
UR - https://www.scopus.com/pages/publications/85108010356
UR - https://www.scopus.com/pages/publications/85108010356#tab=citedBy
U2 - 10.1016/j.pdpdt.2021.102362
DO - 10.1016/j.pdpdt.2021.102362
M3 - Article
C2 - 34062305
AN - SCOPUS:85108010356
SN - 1572-1000
VL - 35
JO - Photodiagnosis and Photodynamic Therapy
JF - Photodiagnosis and Photodynamic Therapy
M1 - 102362
ER -