Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry

Xiaoshuang Chen, Takafumi Seto, Uwe R Kortshagen, Christopher J Hogan

Research output: Contribution to journalArticle

Abstract

Low pressure (<20 Torr) non-thermal plasma flow tube reactors are commonly used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online NP size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radio frequency non-thermal SiH 4 –Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey–Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode ‘mobility equivalent’ diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distribution functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreements were found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negative charge levels to a bipolar charge distribution likely drives aggregation on the plasma boundary.

Original languageEnglish (US)
Article number015002
Pages (from-to)015002
JournalNano Futures
Volume3
Issue number1
DOIs
StatePublished - Mar 1 2019

Fingerprint

Spectrometry
Distribution functions
low pressure
distribution functions
reactors
Ions
Nanoparticles
Plasmas
nanoparticles
collisions
cross sections
synthesis
spectroscopy
ions
analyzers
Process monitoring
outlets
transfer functions
Transfer functions
Plasma flow

Keywords

  • Differential mobility analysis
  • Dusty plasmas
  • Ion mobility spectrometry
  • Online size distribution functions
  • Plasma synthesis
  • Silicon nanoparticles

How much support was provided by MRSEC?

  • Primary

Reporting period for MRSEC

  • Period 5

Cite this

Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry. / Chen, Xiaoshuang; Seto, Takafumi; Kortshagen, Uwe R; Hogan, Christopher J.

In: Nano Futures, Vol. 3, No. 1, 015002, 01.03.2019, p. 015002.

Research output: Contribution to journalArticle

@article{642d1a38363c45448561bf24ccb60872,
title = "Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry",
abstract = "Low pressure (<20 Torr) non-thermal plasma flow tube reactors are commonly used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online NP size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radio frequency non-thermal SiH 4 –Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey–Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode ‘mobility equivalent’ diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distribution functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreements were found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negative charge levels to a bipolar charge distribution likely drives aggregation on the plasma boundary.",
keywords = "Differential mobility analysis, Dusty plasmas, Ion mobility spectrometry, Online size distribution functions, Plasma synthesis, Silicon nanoparticles",
author = "Xiaoshuang Chen and Takafumi Seto and Kortshagen, {Uwe R} and Hogan, {Christopher J}",
year = "2019",
month = "3",
day = "1",
doi = "10.1088/2399-1984/aaff97",
language = "English (US)",
volume = "3",
pages = "015002",
journal = "Nano Futures",
issn = "2399-1984",
publisher = "Institute of Physics Publishing",
number = "1",

}

TY - JOUR

T1 - Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry

AU - Chen, Xiaoshuang

AU - Seto, Takafumi

AU - Kortshagen, Uwe R

AU - Hogan, Christopher J

PY - 2019/3/1

Y1 - 2019/3/1

N2 - Low pressure (<20 Torr) non-thermal plasma flow tube reactors are commonly used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online NP size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radio frequency non-thermal SiH 4 –Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey–Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode ‘mobility equivalent’ diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distribution functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreements were found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negative charge levels to a bipolar charge distribution likely drives aggregation on the plasma boundary.

AB - Low pressure (<20 Torr) non-thermal plasma flow tube reactors are commonly used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online NP size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radio frequency non-thermal SiH 4 –Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey–Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode ‘mobility equivalent’ diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distribution functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreements were found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negative charge levels to a bipolar charge distribution likely drives aggregation on the plasma boundary.

KW - Differential mobility analysis

KW - Dusty plasmas

KW - Ion mobility spectrometry

KW - Online size distribution functions

KW - Plasma synthesis

KW - Silicon nanoparticles

UR - http://www.scopus.com/inward/record.url?scp=85065045373&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065045373&partnerID=8YFLogxK

U2 - 10.1088/2399-1984/aaff97

DO - 10.1088/2399-1984/aaff97

M3 - Article

VL - 3

SP - 015002

JO - Nano Futures

JF - Nano Futures

SN - 2399-1984

IS - 1

M1 - 015002

ER -