Skip to main navigation Skip to search Skip to main content

Detection chain and electronic readout of the QUBIC instrument

  • Guillaume Stankowiak
  • , M. Piat
  • , E. S. Battistelli
  • , G. D'Alessandro
  • , P. De Bernardis
  • , M. D. Petris
  • , M. Gonzalez
  • , L. Grandsire
  • , J. Ch Hamilton
  • , T. D. Hoang
  • , S. Masi
  • , S. Marnieros
  • , A. Mennella
  • , L. Mousset
  • , C. O'Sullivan
  • , D. Prele
  • , A. Tartari
  • , J. P. Thermeau
  • , S. A. Torchinsky
  • , F. Voisin
  • M. Zannoni, P. Ade, J. G. Alberro, A. Almela, G. Amico, L. H. Arnaldi, D. Auguste, J. Aumont, S. Azzoni, S. Banff, B. Belier, A. Baffu, D. Bennett, L. Berge, J. P. Bernard, M. Bersanelli, M. A. Bigot-Sazy, J. Bonaparte, J. Bonis, E. Bunn, D. Burke, D. Buzi, F. Cavaliere, P. Chanial, C. Chapron, R. Charlassier, A. C.C. Cerutti, F. Columbro, A. Coppolecchia, G. De Gasperis, M. D. Leo, S. Dheilly, C. Duca, L. Dumoulin, A. Etchegoyen, A. Fasciszewski, L. P. Ferreyro, D. Fracchia, C. Franceschet, M. M.G. Lerena, K. M. Ganga, B. Garcia, M. E.Garcia Redondo, M. Gaspard, D. Gayer, M. Gervasi, M. Giard, V. Gilles, Y. Giraud-Heraud, M. Gomez Berisso, M. Gradziel, M. R. Hampel, D. Harari, S. Henrot-Versille, F. Incardona, E. Jules, J. Kaplan, C. Kristukat, L. Lamagna, S. Loucatos, T. Louis, B. Maffei, W. Marty, A. Mattei, A. May, M. McCulloch, L. Mele, D. Melo, L. Montier, L. M. Mundo, J. A. Murphy, J. D. Murphy, F. Nati, E. Olivieri, C. Oriol, A. Paiella, F. Pajot, A. Passerini, H. Pastoriza, A. Pelosi, C. Perbost, M. Perciballi, F. Pezzotta, F. Piacentini, L. Piccirillo, G. Pisano, M. Platino, G. Polenta, R. Puddu, D. Rambaud, P. Ringegni, G. E. Romero, E. Rasztocky, J. M. Salum, A. Schillaci, C. Scoccola, S. Scully, S. Spinelli, M. Stolpovskiy, A. D. Supanitsky, P. Timbie, M. Tomasi, G. Tucker, C. Tucker, D. Vigano, N. Vittorio, F. Wicek, M. Wright, A. Zullo

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution

Abstract

The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power.

Original languageEnglish (US)
Title of host publicationMillimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X
EditorsJonas Zmuidzinas, Jian-Rong Gao
PublisherSPIE
ISBN (Electronic)9781510636934
DOIs
StatePublished - 2020
Externally publishedYes
EventMillimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X 2020 - Virtual, Online, United States
Duration: Dec 14 2020 → Dec 22 2020

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume11453
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

ConferenceMillimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X 2020
Country/TerritoryUnited States
CityVirtual, Online
Period12/14/20 → 12/22/20

Bibliographical note

Publisher Copyright:
© COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.

Keywords

  • CMB
  • SQUID
  • TDM
  • TES

Fingerprint

Dive into the research topics of 'Detection chain and electronic readout of the QUBIC instrument'. Together they form a unique fingerprint.