Background: Alloimmunization against D-antigen can cause severe Hemolytic Disease of the Fetus and Newborn (HDFN). Traditionally, anti-D-titers are measured using a saline indirect antiglobulin test (tube testing). Anti-D-titers ≥8 during pregnancy trigger an escalation in maternal care. Tube testing is labor-intensive and known for imprecision. Automated gel-based titration is more sensitive and precise than tube titration for the detection of anti-D. A gel titer correlated with potential fetal anemia has not been established, as studies comparing gel and tube titers provide widely variable results. This multicenter study tested anti-D samples in parallel to characterize the difference in sensitivity between tube and automated gel assays. Study Design and Methods: Patients alloimmunized to RhD had samples tested using tube and automated gel titration methods. A total of 647 samples were tested in parallel. A subset of 141 samples also had anti-D levels quantified using continuous flow analysis (CFA). Controlled lots of R2R2 red blood cells and standardized reagents were utilized. Results: Results demonstrated that gel-based methods yielded mean titers 2.5–3 dilutions higher than tube; this difference diminished at tube titers >128. Notably, several samples previously considered negative by tube were positive by gel. Anti-D levels quantified by CFA demonstrated a good correlation with tube and gel testing (R = 0.75–0.9 for tube; R = 0.85–0.89 for gel). Discussion: A tube titer of 8 to 16 correlates with an automated gel titer of 32–128 when R2R2 cells are used. Results using the CFA method correlate well with tube and gel analyses.

Original languageEnglish (US)
Pages (from-to)94-101
Number of pages8
JournalTransfusion
Volume66
Issue number1
DOIs
StatePublished - Jan 2026

Bibliographical note

Publisher Copyright:
© 2025 The Author(s). Transfusion published by Wiley Periodicals LLC on behalf of AABB.

Keywords

  • D-antigen
  • Rh
  • alloimmunization
  • antibody titer
  • gel-based testing
  • hemolytic disease of the fetus and newborn (HDFN)
  • prenatal screening
  • tube testing

PubMed: MeSH publication types

  • Journal Article
  • Multicenter Study

Fingerprint

Dive into the research topics of 'D-Alloantibody Titration Assessment Study: In Search of a Common Antibody Titration Platform—A BEST Collaborative Study'. Together they form a unique fingerprint.

Cite this