Abstract

The cost of high pressure processing (HPP) and the environmental impact of pulsed electric fields (PEF), HPP and thermal pasteurization of orange juice were estimated in the US. The cost analysis was based on commercial processing conditions that were validated for a 2-month shelf-life of orange juice under refrigeration conditions. Total electricity consumption was estimated to be 38,100 and 1,000,000 k Wh/year for thermal and HPP processing, respectively. Total pasteurization cost of HPP was estimated to be 10.7 ¢/l for processing 16,500,000 l/year (3,000 l/h). Of this, capital costs accounted for 59 % (6.3 ¢/l), labor costs accounted for 37 % (4.0 ¢/l) and utility charges, mainly electricity, accounted for 4 % (0.4 ¢/l). The total HPP cost was 7-folds higher than that of conventional thermal processing (1.5 ¢/l). The equivalent CO 2 emission was 90,000 kg for thermal processing and 700,000 and 773,000 kg for PEF and HPP, respectively. This corresponds to an increase between 7- and 8-folds in comparison to the thermal processing. Increasing the production output by 2- to 6-folds reduced the total production costs of nonthermal processing by 50-75 %. A deeper knowledge of the processing costs and environmental impact of nonthermal technologies will afford companies a better understanding of the benefits and limitations of these novel systems.

Original languageEnglish (US)
Pages (from-to)1928-1937
Number of pages10
JournalFood and Bioprocess Technology
Volume7
Issue number7
DOIs
StatePublished - Jan 1 2014

Fingerprint

Pasteurization
cost analysis
pulsed electric fields
high pressure treatment
pasteurization
Environmental impact
environmental impact
Hot Temperature
Electric fields
heat
Pressure
Costs and Cost Analysis
Processing
Costs
orange juice
heat treatment
electricity
Electricity
nonthermal processing
refrigeration

Keywords

  • Cost analysis
  • Environmental impact
  • High pressure
  • Pulsed electric fields
  • Thermal processing

Cite this

Cost Analysis and Environmental Impact of Pulsed Electric Fields and High Pressure Processing in Comparison with Thermal Pasteurization. / Sampedro, Fernando; McAloon, A.; Yee, W.; Fan, X.; Geveke, D. J.

In: Food and Bioprocess Technology, Vol. 7, No. 7, 01.01.2014, p. 1928-1937.

Research output: Contribution to journalArticle

@article{4c707bd6ab574d9f9bdc09540ca62939,
title = "Cost Analysis and Environmental Impact of Pulsed Electric Fields and High Pressure Processing in Comparison with Thermal Pasteurization",
abstract = "The cost of high pressure processing (HPP) and the environmental impact of pulsed electric fields (PEF), HPP and thermal pasteurization of orange juice were estimated in the US. The cost analysis was based on commercial processing conditions that were validated for a 2-month shelf-life of orange juice under refrigeration conditions. Total electricity consumption was estimated to be 38,100 and 1,000,000 k Wh/year for thermal and HPP processing, respectively. Total pasteurization cost of HPP was estimated to be 10.7 ¢/l for processing 16,500,000 l/year (3,000 l/h). Of this, capital costs accounted for 59 {\%} (6.3 ¢/l), labor costs accounted for 37 {\%} (4.0 ¢/l) and utility charges, mainly electricity, accounted for 4 {\%} (0.4 ¢/l). The total HPP cost was 7-folds higher than that of conventional thermal processing (1.5 ¢/l). The equivalent CO 2 emission was 90,000 kg for thermal processing and 700,000 and 773,000 kg for PEF and HPP, respectively. This corresponds to an increase between 7- and 8-folds in comparison to the thermal processing. Increasing the production output by 2- to 6-folds reduced the total production costs of nonthermal processing by 50-75 {\%}. A deeper knowledge of the processing costs and environmental impact of nonthermal technologies will afford companies a better understanding of the benefits and limitations of these novel systems.",
keywords = "Cost analysis, Environmental impact, High pressure, Pulsed electric fields, Thermal processing",
author = "Fernando Sampedro and A. McAloon and W. Yee and X. Fan and Geveke, {D. J.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s11947-014-1298-6",
language = "English (US)",
volume = "7",
pages = "1928--1937",
journal = "Food and Bioprocess Technology",
issn = "1935-5130",
publisher = "Springer New York",
number = "7",

}

TY - JOUR

T1 - Cost Analysis and Environmental Impact of Pulsed Electric Fields and High Pressure Processing in Comparison with Thermal Pasteurization

AU - Sampedro, Fernando

AU - McAloon, A.

AU - Yee, W.

AU - Fan, X.

AU - Geveke, D. J.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - The cost of high pressure processing (HPP) and the environmental impact of pulsed electric fields (PEF), HPP and thermal pasteurization of orange juice were estimated in the US. The cost analysis was based on commercial processing conditions that were validated for a 2-month shelf-life of orange juice under refrigeration conditions. Total electricity consumption was estimated to be 38,100 and 1,000,000 k Wh/year for thermal and HPP processing, respectively. Total pasteurization cost of HPP was estimated to be 10.7 ¢/l for processing 16,500,000 l/year (3,000 l/h). Of this, capital costs accounted for 59 % (6.3 ¢/l), labor costs accounted for 37 % (4.0 ¢/l) and utility charges, mainly electricity, accounted for 4 % (0.4 ¢/l). The total HPP cost was 7-folds higher than that of conventional thermal processing (1.5 ¢/l). The equivalent CO 2 emission was 90,000 kg for thermal processing and 700,000 and 773,000 kg for PEF and HPP, respectively. This corresponds to an increase between 7- and 8-folds in comparison to the thermal processing. Increasing the production output by 2- to 6-folds reduced the total production costs of nonthermal processing by 50-75 %. A deeper knowledge of the processing costs and environmental impact of nonthermal technologies will afford companies a better understanding of the benefits and limitations of these novel systems.

AB - The cost of high pressure processing (HPP) and the environmental impact of pulsed electric fields (PEF), HPP and thermal pasteurization of orange juice were estimated in the US. The cost analysis was based on commercial processing conditions that were validated for a 2-month shelf-life of orange juice under refrigeration conditions. Total electricity consumption was estimated to be 38,100 and 1,000,000 k Wh/year for thermal and HPP processing, respectively. Total pasteurization cost of HPP was estimated to be 10.7 ¢/l for processing 16,500,000 l/year (3,000 l/h). Of this, capital costs accounted for 59 % (6.3 ¢/l), labor costs accounted for 37 % (4.0 ¢/l) and utility charges, mainly electricity, accounted for 4 % (0.4 ¢/l). The total HPP cost was 7-folds higher than that of conventional thermal processing (1.5 ¢/l). The equivalent CO 2 emission was 90,000 kg for thermal processing and 700,000 and 773,000 kg for PEF and HPP, respectively. This corresponds to an increase between 7- and 8-folds in comparison to the thermal processing. Increasing the production output by 2- to 6-folds reduced the total production costs of nonthermal processing by 50-75 %. A deeper knowledge of the processing costs and environmental impact of nonthermal technologies will afford companies a better understanding of the benefits and limitations of these novel systems.

KW - Cost analysis

KW - Environmental impact

KW - High pressure

KW - Pulsed electric fields

KW - Thermal processing

UR - http://www.scopus.com/inward/record.url?scp=84901663654&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901663654&partnerID=8YFLogxK

U2 - 10.1007/s11947-014-1298-6

DO - 10.1007/s11947-014-1298-6

M3 - Article

VL - 7

SP - 1928

EP - 1937

JO - Food and Bioprocess Technology

JF - Food and Bioprocess Technology

SN - 1935-5130

IS - 7

ER -