TY - JOUR
T1 - Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging
AU - Pfeuffer, Josef
AU - Van Moortele, Pierre Francois De
AU - Ugurbil, Kamil
AU - Hu, Xiaoping
AU - Glover, Gary H.
PY - 2002
Y1 - 2002
N2 - In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "dynamic off-resonance in k-space" (DORK) was developed. The correction uses phase information from the center of k-space and a navigator echo and is illustrated with dynamic scans of single-shot and segmented EPI and, for the first time, spiral imaging of the human brain at 7 T. Image noise in the respiratory spectrum was measured with an edge operator. The DORK correction significantly reduced respiration-induced noise (image shift for EPI, blurring for spiral, ghosting for segmented acquisition). While spiral imaging was found to exhibit less noise than EPI before correction, the residual noise after the DORK correction was comparable. The correction is simple to apply and can correct for other sources of frequency drift and fluctuations in dynamic imaging.
AB - In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "dynamic off-resonance in k-space" (DORK) was developed. The correction uses phase information from the center of k-space and a navigator echo and is illustrated with dynamic scans of single-shot and segmented EPI and, for the first time, spiral imaging of the human brain at 7 T. Image noise in the respiratory spectrum was measured with an edge operator. The DORK correction significantly reduced respiration-induced noise (image shift for EPI, blurring for spiral, ghosting for segmented acquisition). While spiral imaging was found to exhibit less noise than EPI before correction, the residual noise after the DORK correction was comparable. The correction is simple to apply and can correct for other sources of frequency drift and fluctuations in dynamic imaging.
KW - Functional magnetic resonance imaging
KW - Global off-resonance
KW - Physiological artifacts
KW - Respiration artifacts
UR - http://www.scopus.com/inward/record.url?scp=0036160977&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036160977&partnerID=8YFLogxK
U2 - 10.1002/mrm.10065
DO - 10.1002/mrm.10065
M3 - Article
C2 - 11810679
AN - SCOPUS:0036160977
SN - 0740-3194
VL - 47
SP - 344
EP - 353
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 2
ER -