TY - GEN
T1 - Continuous DoI determination by gaussian modelling of linear and non-linear scintillation light distributions
AU - Pani, Roberto
AU - Nourbakhsh, Shervin
AU - Pani, Priscilla
AU - Bennati, Paolo
AU - Lo Meo, Sergio
AU - Cinti, Maria Nerina
AU - Pellegrini, Rosanna
AU - Cassano, Bartolomeo
AU - Bettiol, Marco
AU - Scafe, Raffaele
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2012
Y1 - 2012
N2 - The Depth of Interaction (DoI) detection is crucial in many medical imaging applications such as small ring PET and high resolution SPECT. In this work we investigate the possibility to discriminate the DoI using continuous crystals. A LaBr 3(Ce) crystal has been used in the detection system for its intrinsic high light yield, that especially at low energies (e.g. 140 keV) reduces considerably the statistical uncertainties increasing the DoI discrimination power. The innovative suggestion of this work is the use of spectrometric observables to discriminate events on top and bottom of the crystal, under the hypothesis that scintillation light distributions can be parameterized by a gaussian model. The spread of the light cone (σ) is proportional to the DoI simply by geometrical considerations, but under the gaussian hypothesis relations between the spectrometric variables (maximum high I and integral of the distribution N) and the DoI become a straightforward consequence. Two methods are proposed and discussed: a linear treatment of the light distribution and a non linear (quadratic) manipulation of it. The expected correlations between the spectrometric variables (N and I), according to the gaussian model, are checked using a specific Monte Carlo simulation of the experimental apparatus. Those are then compared with experimental data obtained irradiating the LaBr3:Ce crystal with a Tc 99m collimated source. A close agreement between experimental data and MC is verified. Finally, a preliminary test on experimental data has been performed irradiating the crystal with a Co 57 source, in order to investigate the strong dependence of the non linear manipulation of the light distribution to the DoI.
AB - The Depth of Interaction (DoI) detection is crucial in many medical imaging applications such as small ring PET and high resolution SPECT. In this work we investigate the possibility to discriminate the DoI using continuous crystals. A LaBr 3(Ce) crystal has been used in the detection system for its intrinsic high light yield, that especially at low energies (e.g. 140 keV) reduces considerably the statistical uncertainties increasing the DoI discrimination power. The innovative suggestion of this work is the use of spectrometric observables to discriminate events on top and bottom of the crystal, under the hypothesis that scintillation light distributions can be parameterized by a gaussian model. The spread of the light cone (σ) is proportional to the DoI simply by geometrical considerations, but under the gaussian hypothesis relations between the spectrometric variables (maximum high I and integral of the distribution N) and the DoI become a straightforward consequence. Two methods are proposed and discussed: a linear treatment of the light distribution and a non linear (quadratic) manipulation of it. The expected correlations between the spectrometric variables (N and I), according to the gaussian model, are checked using a specific Monte Carlo simulation of the experimental apparatus. Those are then compared with experimental data obtained irradiating the LaBr3:Ce crystal with a Tc 99m collimated source. A close agreement between experimental data and MC is verified. Finally, a preliminary test on experimental data has been performed irradiating the crystal with a Co 57 source, in order to investigate the strong dependence of the non linear manipulation of the light distribution to the DoI.
UR - http://www.scopus.com/inward/record.url?scp=84858684176&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84858684176&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2011.6152614
DO - 10.1109/NSSMIC.2011.6152614
M3 - Conference contribution
AN - SCOPUS:84858684176
SN - 9781467301183
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3386
EP - 3389
BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
T2 - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Y2 - 23 October 2011 through 29 October 2011
ER -