Abstract
Coronary magnetic resonance imaging (MRI) is a noninvasive imaging modality for diagnosis of coronary artery disease. One of the limitations of coronary MRI is its long acquisition time due to the need of imaging with high spatial resolution and constraints on respiratory and cardiac motions. Compressed sensing (CS) has been recently utilized to accelerate image acquisition in MRI. In this paper, we develop an improved CS reconstruction method, Bayesian least squares-Gaussian scale mixture (BLS-GSM), that uses dependencies of wavelet domain coefficients to reduce the observed blurring and reconstruction artifacts in coronary MRI using traditional l1 regularization. Images of left and right coronary MRI was acquired in 7 healthy subjects with fully-sampled k-space data. The data was retrospectively undersampled using acceleration rates of 2, 4, 6, and 8 and reconstructed using l1 thresholding, l 1 minimization and BLS-GSM thresholding. Reconstructed right and left coronary images were compared with fully-sampled reconstructions in vessel sharpness and subjective image quality (14 for poor-excellent). Mean square error (MSE) was also calculated for each reconstruction. There were no significant differences between the fully sampled image score versus rate 2, 4, or 6 for BLS-GSM for both right and left coronaries (= N.S.). However, for l1 thresholding significant differences (p<0.05) were observed for rates higher than 2 and 4 for right and left coronaries respectively. l 1 minimization also yields images with lower scores compared to the reference for rates higher than 4 for both coronaries. These results were consistent with the quantitative vessel sharpness readings. BLS-GSM allows acceleration of coronary MRI with acceleration rates beyond what can be achieved with l1 regularization.
Original language | English (US) |
---|---|
Article number | 5607310 |
Pages (from-to) | 1090-1099 |
Number of pages | 10 |
Journal | IEEE Transactions on Medical Imaging |
Volume | 30 |
Issue number | 5 |
DOIs | |
State | Published - May 2011 |
Bibliographical note
Funding Information:Manuscript received June 01, 2010; revised September 17, 2010; accepted October 13, 2010. Date of publication October 21, 2010; date of current version May 04, 2011. The project described was supported by NIH R01EB008743-01A2, AHA SDG-0730339N and NIH UL1 RR025758-01, Harvard Clinical and Translational Science Center, from the National Center for Research Resources. Asterisk indicates corresponding author. *M. Akçakaya is with the School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138 USA, and with the Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215 USA (e-mail: [email protected]).
Keywords
- Accelerated imaging
- compressed sensing
- coronary artery disease
- coronary magnetic resonance imaging (MRI)
- wavelet domain dependencies