TY - JOUR
T1 - Comparison of saliva and serum for human immunodeficiency virus type 1 antibody testing in Uganda using a rapid recombinant assay
AU - Grant, Robert M.
AU - Piwowar, Estelle M.
AU - Katongole-Mbidde, Edward
AU - Muzawalu, Waiswa
AU - Rugera, Simon
AU - Abima, John
AU - Stramer, Susan L.
AU - Kataaha, Peter
AU - Jackson, Brooks
PY - 1996
Y1 - 1996
N2 - The accuracy and acceptability of saliva human immunodeficiency virus type 1 (HIV-1) antibody testing were compared with serum testing in a study of paired specimens from HIV-1-seropositive and HIV-1-seronegative Ugandan adults attending a clinic for sexually transmitted diseases. Saliva collection was performed with the Omni-sal device (Saliva Diagnostic Systems, Vancouver, Wash.), and antibody testing was performed by a rapid filter paper assay (Test-Pack; Abbott Laboratories, Abbott Park, Ill.). Relative to serum testing, the sensitivity of saliva testing was 95% (195 of 205) and the specificity was 99% (295 of 297). The sensitivity of saliva testing was higher for patients with elevated levels of beta-2 microglobulin in sera and greater numbers of HIV-1-related symptoms. Pre- and poststudy interviews indicated that saliva testing did not foster inordinate fears of saliva exposure. The development of saliva tests that are inexpensive and do not require electricity is needed.
AB - The accuracy and acceptability of saliva human immunodeficiency virus type 1 (HIV-1) antibody testing were compared with serum testing in a study of paired specimens from HIV-1-seropositive and HIV-1-seronegative Ugandan adults attending a clinic for sexually transmitted diseases. Saliva collection was performed with the Omni-sal device (Saliva Diagnostic Systems, Vancouver, Wash.), and antibody testing was performed by a rapid filter paper assay (Test-Pack; Abbott Laboratories, Abbott Park, Ill.). Relative to serum testing, the sensitivity of saliva testing was 95% (195 of 205) and the specificity was 99% (295 of 297). The sensitivity of saliva testing was higher for patients with elevated levels of beta-2 microglobulin in sera and greater numbers of HIV-1-related symptoms. Pre- and poststudy interviews indicated that saliva testing did not foster inordinate fears of saliva exposure. The development of saliva tests that are inexpensive and do not require electricity is needed.
UR - http://www.scopus.com/inward/record.url?scp=0029958558&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029958558&partnerID=8YFLogxK
U2 - 10.1128/cdli.3.6.640-644.1996
DO - 10.1128/cdli.3.6.640-644.1996
M3 - Article
C2 - 8914752
AN - SCOPUS:0029958558
SN - 1071-412X
VL - 3
SP - 640
EP - 644
JO - Clinical and Diagnostic Laboratory Immunology
JF - Clinical and Diagnostic Laboratory Immunology
IS - 6
ER -