Comparing the Accuracy of 2 Point-of-Care Lipid Testing Devices

Karen M Bastianelli, Stacey Ledin, Jennifer Chen

Research output: Contribution to journalArticlepeer-review

31 Scopus citations

Abstract

Background: Device manufacturers have improved technology since studies were last published, thus warranting an updated analysis. Objective: Two point-of-care (POC) cholesterol testing devices were directly compared to a venous sample to determine device accuracy. Methods: Institutional review board (IRB)-approved study collected finger-stick blood samples analyzed by Cholestech LDX (Cholestech Corporation, Hayward, California) and CardioChek Plus (Polymer Technology Systems Inc, Indianapolis, Indiana) devices and compared to venous blood for 30 study participants. Statistical analyses were completed using StatisPro. Intraclass correlation coefficients were generated, and the average difference expected to be within the industry standards of total cholesterol (TC; ±10%), high-density lipoprotein (HDL) cholesterol (±12%), and triglycerides (TG; ±15%). Results: The POC devices produced clinically equivalent values when compared to the same patients' samples analyzed in a reference laboratory. The average difference calculated from the actual individual paired percentage bias with the Integra analyzer: venous - TC -3.8%, HDL -6.9%, TG -1.8%; CardioChek - TC -7.8%, HDL -6.2%, TG 5.1%; and Cholestech - TC 0.5%, HDL -4.5%, TG -3.3%. The average of the actual paired percentage bias with the Roche Cobas analyzer: CardioChek - TC -4.2%, HDL 0.8%, TG 7.0% and Cholestech - TC 4.6%, HDL 2.6%, TG -1.6%. Conclusion: Both screening devices operated within industry accuracy standards.

Original languageEnglish (US)
Pages (from-to)490-497
Number of pages8
JournalJournal of Pharmacy Practice
Volume30
Issue number5
DOIs
StatePublished - Oct 1 2017

Bibliographical note

Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The authors acknowledge the University of Minnesota—College of Pharmacy Faculty Grants Award Program for funding this project, as well as research support from Polymer Technology Systems Inc, Indianapolis, Indiana.

Publisher Copyright:
© The Author(s) 2016.

Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.

Keywords

  • cholesterol screening
  • community outreach
  • health fair
  • point of care

Fingerprint

Dive into the research topics of 'Comparing the Accuracy of 2 Point-of-Care Lipid Testing Devices'. Together they form a unique fingerprint.

Cite this