Common-duty-ratio control of input-series connected modular DC-DC converters with active input voltage and load-current sharing

Ramesh Giri, Vijay Choudhary, Raja Ayyanar, Ned Mohan

Research output: Contribution to journalArticlepeer-review

244 Scopus citations

Abstract

This paper proposes a simple control method to achieve active sharing of input voltage and load current among modular converters that are connected in series at the input and in parallel at the output. The input-series connection enables a fully modular power-system architecture, where low voltage and low power modules can be connected in any combination at the input and/or at the output, to realize any given specifications. Further, the input-series connection enables the use of low-voltage MOSFETs that are optimized for very low RDSON, thus, resulting in lower conduction losses. In the proposed scheme, the duty ratio to all the converter modules connected in input-series and output-parallel (ISOP) configuration is made common. This scheme does not require a dedicated input-voltage or load-current-share controller. It relies on the inherent self-correcting characteristic of the ISOP connection when the duty ratio of all the converters is the same. The proposed scheme is analyzed using the average model of a forward converter. The stability and performance of the scheme are verified through numerical simulation, both in frequency domain and in time domain. The proposed control method is also validated on an experimental prototype ISOP system comprising of two forward converters.

Original languageEnglish (US)
Pages (from-to)1101-1111
Number of pages11
JournalIEEE Transactions on Industry Applications
Volume42
Issue number4
DOIs
StatePublished - Jul 2006

Bibliographical note

Funding Information:
Paper IPCSD-06-023, presented at the 2003 IEEE Applied Power Electronics Conference and Exposition, Miami Beach, FL, February 9–13, and approved for publication in the IEEE TRANSACTIONS ON INDUSTRY APPLICATION by the Industrial Power Converter Committee of the IEEE Industry Applications Society. Manuscript submitted for review November 1, 2003 and released for publication April 10, 2006. This work was supported in part by the Office of Naval Research (ONR) under Award N00014-03-1-0802 and Award N00014-05-1-0622.

Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.

Keywords

  • Common duty ratio
  • Fault tolerance
  • Input series and output parallel (ISOP)
  • Input-series connection
  • Input-voltage sharing
  • Load-current sharing
  • Modular dc-dc converters

Fingerprint

Dive into the research topics of 'Common-duty-ratio control of input-series connected modular DC-DC converters with active input voltage and load-current sharing'. Together they form a unique fingerprint.