T1 - Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room
AU - Dumas, Constantine
AU - Wahr, Joyce A.
AU - Tremper, Kevin K.
PY - 1996
Y1 - 1996
N2 - The frequency and nature of spurious pulse oximetry readings were compared using both a conventional pulse oximeter (CPO) and a prototype Masimo signal extraction technology pulse oximeter (Masimo SET(TM)). At a university hospital, 50 ASA physical status I-IV adult patients who underwent general or spinal-epidural anesthesia were selected from a group of 250 patients on the basis of high-alarm generation with routine postoperative pulse oximetry. Pulse oximetry data were recorded simultaneously from both devices with a computer. Overall, the CPO alarm frequency (i.e., oxygen saturation < 90%, or complete signal loss) was once every 13 min, and 87% of these alarms were considered false. Alarms were considered false based on reference electrocardiographs (16 patients), arterial blood gases (7 patients), and clinical assessment. The prototype Masimo SET(TM) device alarm frequency was once every 30 min, and 59% of these were considered false. During arm motion with 15 patients, the CPO device produced spurious signals on 54 occasions compared with five for the prototype Masimo SET(TM). The incidence of artifactual pulse oximetry events during patient motion appear to be substantially reduced with the prototype Masimo SET(TM) device, relative to a CPO device.
AB - The frequency and nature of spurious pulse oximetry readings were compared using both a conventional pulse oximeter (CPO) and a prototype Masimo signal extraction technology pulse oximeter (Masimo SET(TM)). At a university hospital, 50 ASA physical status I-IV adult patients who underwent general or spinal-epidural anesthesia were selected from a group of 250 patients on the basis of high-alarm generation with routine postoperative pulse oximetry. Pulse oximetry data were recorded simultaneously from both devices with a computer. Overall, the CPO alarm frequency (i.e., oxygen saturation < 90%, or complete signal loss) was once every 13 min, and 87% of these alarms were considered false. Alarms were considered false based on reference electrocardiographs (16 patients), arterial blood gases (7 patients), and clinical assessment. The prototype Masimo SET(TM) device alarm frequency was once every 30 min, and 59% of these were considered false. During arm motion with 15 patients, the CPO device produced spurious signals on 54 occasions compared with five for the prototype Masimo SET(TM). The incidence of artifactual pulse oximetry events during patient motion appear to be substantially reduced with the prototype Masimo SET(TM) device, relative to a CPO device.
UR - http://www.scopus.com/inward/record.url?scp=0030017260&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030017260&partnerID=8YFLogxK
U2 - 10.1097/00000539-199608000-00012
DO - 10.1097/00000539-199608000-00012
M3 - Article
C2 - 8694304
AN - SCOPUS:0030017260
SN - 0003-2999
VL - 83
SP - 269
EP - 272
JO - Anesthesia and analgesia
JF - Anesthesia and analgesia
IS - 2
ER -