TY - GEN
T1 - "capacitive" pulse shapes for platinum cuff electrodes
AU - Woods, Virginia M.
AU - Triantis, Iasonas F.
AU - Agathos, Catherine
AU - Toumazou, Christofer
PY - 2011
Y1 - 2011
N2 - Artificial electrical stimulation of the peripheral nervous system is an established therapy for several pathologies and motor impairments. Therapeutic outcomes can be improved with targeted patterns of neural activation, but the required signal amplitudes to achieve this response exceed the limits for safe stimulation. This can lead to electrode corrosion and tissue damage. In this paper, we present a novel approach to pulse shape design based on the properties of the electrode-electrolyte interface. We aim to improve electrode stability at higher voltages by exploiting the potential-independent mechanisms of charge injection. We identified signal parameters associated with capacitive current flow at the platinum interface and incorporated these features into the design of cathodal pulse shapes. A pulse shape comprising 4 high-frequency capacitive harmonics demonstrated a 40 fold performance benefit compared to a conventional square pulse, but irreversible reactions could not be completely avoided during current flow. However, the enhanced electrode stability with the capacitive pulse shapes suggests further optimization of pulse designs according to a surface stability function might allow for safe stimulation with greater electrode voltages.
AB - Artificial electrical stimulation of the peripheral nervous system is an established therapy for several pathologies and motor impairments. Therapeutic outcomes can be improved with targeted patterns of neural activation, but the required signal amplitudes to achieve this response exceed the limits for safe stimulation. This can lead to electrode corrosion and tissue damage. In this paper, we present a novel approach to pulse shape design based on the properties of the electrode-electrolyte interface. We aim to improve electrode stability at higher voltages by exploiting the potential-independent mechanisms of charge injection. We identified signal parameters associated with capacitive current flow at the platinum interface and incorporated these features into the design of cathodal pulse shapes. A pulse shape comprising 4 high-frequency capacitive harmonics demonstrated a 40 fold performance benefit compared to a conventional square pulse, but irreversible reactions could not be completely avoided during current flow. However, the enhanced electrode stability with the capacitive pulse shapes suggests further optimization of pulse designs according to a surface stability function might allow for safe stimulation with greater electrode voltages.
UR - https://www.scopus.com/pages/publications/84862301478
UR - https://www.scopus.com/pages/publications/84862301478#tab=citedBy
U2 - 10.1109/IEMBS.2011.6091337
DO - 10.1109/IEMBS.2011.6091337
M3 - Conference contribution
C2 - 22255560
AN - SCOPUS:84862301478
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 5408
EP - 5411
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -