TY - JOUR
T1 - Bridging to transplant with the HeartMate left ventricular assist device
T2 - The Columbia Presbyterian 12-year experience
AU - Morgan, Jeffrey A.
AU - John, Ranjit
AU - Rao, Vivek
AU - Weinberg, Alan D.
AU - Lee, Brian J.
AU - Mazzeo, Pamela A.
AU - Flannery, Margaret R.
AU - Chen, Jonathan M.
AU - Oz, Mehmet C.
AU - Naka, Yoshifumi
PY - 2004/5
Y1 - 2004/5
N2 - Objective: Implantation of a left ventricular assist device as a bridge to transplantation has become an acceptable approach for patients with end-stage heart failure. Our long-term results with 3 Thoratec HeartMate devices are presented to outline improvements in successful bridging to transplantation and post-transplant survival. Methods: From August 1990 through January 2003, 243 patients underwent implantation of Thoratec HeartMate devices as a bridge to transplantation. This included 52 (21.4%) pneumatic devices, 17 (7.0%) dual-lead vented electric devices, and 174 (71.6%) single-lead' vented electric devices. Results: Mean age was 49.7 ± 13.7 years. Mean support time was 78.1 ± 82.9 days (0-541). Bridging success increased from 63.5% (n = 33) for pneumatic devices to 64.7% (n = 11) for dual-lead vented electric devices and 72.4% (n = 126) for single-lead vented electric devices (P = .005). Posttransplant 1-, 3-, and 5-year actuarial survival increased from 87.5%, 78.1%, and 71.9% in patients with pneumatic devices to 91.5%, 86.9%, and 81.3%, respectively, for patients with single-lead vented electric devices. Device infection and malfunction occurred in 17.7% (n = 43) and 12.8% (n = 31) of patients, respectively. Conclusions: Successful bridging to transplantation and posttransplant survival has improved over time. Left ventricular assist devices have become increasingly more effective in bridging patients with end-stage heart failure to transplantation. This is likely due to a combination of better patient selection, improvements in clinical practice, and evolution in device design.
AB - Objective: Implantation of a left ventricular assist device as a bridge to transplantation has become an acceptable approach for patients with end-stage heart failure. Our long-term results with 3 Thoratec HeartMate devices are presented to outline improvements in successful bridging to transplantation and post-transplant survival. Methods: From August 1990 through January 2003, 243 patients underwent implantation of Thoratec HeartMate devices as a bridge to transplantation. This included 52 (21.4%) pneumatic devices, 17 (7.0%) dual-lead vented electric devices, and 174 (71.6%) single-lead' vented electric devices. Results: Mean age was 49.7 ± 13.7 years. Mean support time was 78.1 ± 82.9 days (0-541). Bridging success increased from 63.5% (n = 33) for pneumatic devices to 64.7% (n = 11) for dual-lead vented electric devices and 72.4% (n = 126) for single-lead vented electric devices (P = .005). Posttransplant 1-, 3-, and 5-year actuarial survival increased from 87.5%, 78.1%, and 71.9% in patients with pneumatic devices to 91.5%, 86.9%, and 81.3%, respectively, for patients with single-lead vented electric devices. Device infection and malfunction occurred in 17.7% (n = 43) and 12.8% (n = 31) of patients, respectively. Conclusions: Successful bridging to transplantation and posttransplant survival has improved over time. Left ventricular assist devices have become increasingly more effective in bridging patients with end-stage heart failure to transplantation. This is likely due to a combination of better patient selection, improvements in clinical practice, and evolution in device design.
UR - http://www.scopus.com/inward/record.url?scp=2342437924&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=2342437924&partnerID=8YFLogxK
U2 - 10.1016/j.jtcvs.2003.07.035
DO - 10.1016/j.jtcvs.2003.07.035
M3 - Article
C2 - 15115987
AN - SCOPUS:2342437924
SN - 0022-5223
VL - 127
SP - 1309
EP - 1316
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
IS - 5
ER -