T1 - AUTOMATED NONINVASIVE DETERMINATION OF MIXED VENOUS pCO//2.
AU - Leavell, Keith
AU - Finkelstein, Stanley M.
AU - Warwick, Warren J.
AU - Budd, Jeffrey R.
PY - 1986/9
Y1 - 1986/9
N2 - A totally automated, laboratory computer-controlled noninvasive system has been developed to determine mixed venous pCO//2 by an equilibrium rebreathing method or by an exponential compartmental analysis for cases in which equilibrium is not achieved. A gas mixture is charged to a 2-liter anesthesia bag contained in a thermostatically controlled chamber used to maintain the temperature at 37 degree C. This bag is connected to a rebreathing circuit controlled by a minicomputer. The subject breathes from a mouthpiece attached to a two-way valve and rebreathes the gas mixture for a period of 30 seconds. Exchange of CO//2 takes place between lungs and rebreathing bag, and the concentration of CO//2 is continuously monitored by a mass spectrometer. After a period of time, the concentration of CO//2 in the rebreathing bag, the alveoli, and the mixed venous blood come into equilibrium, demonstrated by a plateau on the record of CO//2 concentration vs. time. Compartmental analysis predicts the mixed venous pCO//2 even if an equilibrium is not established.
AB - A totally automated, laboratory computer-controlled noninvasive system has been developed to determine mixed venous pCO//2 by an equilibrium rebreathing method or by an exponential compartmental analysis for cases in which equilibrium is not achieved. A gas mixture is charged to a 2-liter anesthesia bag contained in a thermostatically controlled chamber used to maintain the temperature at 37 degree C. This bag is connected to a rebreathing circuit controlled by a minicomputer. The subject breathes from a mouthpiece attached to a two-way valve and rebreathes the gas mixture for a period of 30 seconds. Exchange of CO//2 takes place between lungs and rebreathing bag, and the concentration of CO//2 is continuously monitored by a mass spectrometer. After a period of time, the concentration of CO//2 in the rebreathing bag, the alveoli, and the mixed venous blood come into equilibrium, demonstrated by a plateau on the record of CO//2 concentration vs. time. Compartmental analysis predicts the mixed venous pCO//2 even if an equilibrium is not established.
UR - http://www.scopus.com/inward/record.url?scp=0022781156&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0022781156&partnerID=8YFLogxK
M3 - Article
C2 - 3097463
AN - SCOPUS:0022781156
SN - 0090-6689
VL - 20
SP - 248
EP - 254
JO - Medical Instrumentation
JF - Medical Instrumentation
IS - 5
ER -