T1 - Automated compression device for viscoelasticity imaging
AU - Nabavizadeh, Alireza
AU - Kinnick, Randall R.
AU - Bayat, Mahdi
AU - Amador, Carolina
AU - Urban, Matthew W
AU - Alizad, Azra
AU - Fatemi, Mostafa
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2017/7
Y1 - 2017/7
N2 - Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-andhold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T1 and T2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T1 and T2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.
AB - Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-andhold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T1 and T2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T1 and T2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.
KW - Creep response
KW - Retardation time
KW - Ultrasound
KW - Viscoelasticity
UR - http://www.scopus.com/inward/record.url?scp=85026739594&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85026739594&partnerID=8YFLogxK
U2 - 10.1109/TBME.2016.2612541
DO - 10.1109/TBME.2016.2612541
M3 - Article
C2 - 28113299
AN - SCOPUS:85026739594
SN - 0018-9294
VL - 64
SP - 1535
EP - 1546
JO - IEEE Transactions on Biomedical Engineering
JF - IEEE Transactions on Biomedical Engineering
IS - 7
M1 - 7574328
ER -