Appropriateness and outcomes of hospitalized patients telemetry monitored for cardiac arrhythmias in accordance with the American Heart Association Practice Standards–A multicenter study

Marianne Sætrang Holm, Nina Fålun, Trond Røed Pettersen, Bjørn Bendz, Roy Miodini Nilsen, Jørund Langørgen, Alf Inge Larsen, Marianne Laastad Sørensen, Kristin E. Sandau, Tone Merete Norekvål

Research output: Contribution to journalArticlepeer-review

Abstract

Background: To the best of our knowledge, no prospective research studies have compared clinical practice to the American Heart Association (AHA) updated practice standards for in-hospital telemetry monitoring. Objectives: Our aims were therefore (1) to investigate how patients were assigned to telemetry monitoring in accordance with the AHA's updated practice standards, (2) to determine the number and type of arrhythmic events, and (3) to describe subsequent changes in clinical management. Methods: This prospective multicenter study included 1154 patients at three university hospitals in Norway. Data were collected 24/7 over a four-week period, with follow-up measurements from telemetry admission until hospital discharge. Results: Of patients assigned to telemetry, 67 % (n = 767) met practice standards, corresponding to AHA Class I or II. Patients were predominantly men (65 %, n = 748), and the mean age was 65 years (SD ±16). The study included both patients with cardiac and non-cardiac diagnoses from various medical and surgical departments throughout the hospitals. Ninety-one percent of the patients in Class III were monitored based on indications that were reclassified from Class II to Class III (not indicated) in the updated practice standards (patients admitted with chest pain or post-percutaneous coronary intervention (PCI) without complications). Overall, arrhythmic events occurred in 37 % (n = 424) of patients, and they occurred in all classes. Eighteen percent (n = 59) of arrhythmic events occurred in Class III. Of all arrhythmias, 3 % (n = 14) were life threatening, and all of them occurring within Class I. Telemetry monitoring led to changes in clinical management in 22 % (n = 257) of patients due to clinical alarms, of which 71 % (n = 182) were related to medication management. Conclusions: Most patients were appropriately monitored according to the AHA practice standards, meeting Class I and II. Arrhythmias occurred in all classes, but life-threatening arrhythmias only occurred in patients in Class I. However, a daily re-assessment of each patient's telemetry indication is warranted.

Original languageEnglish (US)
Pages (from-to)217-226
Number of pages10
JournalHeart and Lung
Volume68
DOIs
StatePublished - Nov 1 2024

Bibliographical note

Publisher Copyright:
© 2024 The Author(s)

Keywords

  • AHA practice standards
  • Arrhythmias
  • Classification
  • Telemetry monitoring

PubMed: MeSH publication types

  • Journal Article

Fingerprint

Dive into the research topics of 'Appropriateness and outcomes of hospitalized patients telemetry monitored for cardiac arrhythmias in accordance with the American Heart Association Practice Standards–A multicenter study'. Together they form a unique fingerprint.

Cite this