TY - JOUR
T1 - An Instrumented Urethral Catheter with a Distributed Array of Iontronic Force Sensors
AU - Zhang, Ye
AU - Ahmadi, Mahdi
AU - Timm, Gerald
AU - Sezen, Serdar
AU - Rajamani, Rajesh
N1 - Publisher Copyright:
© 2020, Biomedical Engineering Society.
PY - 2020/5/6
Y1 - 2020/5/6
N2 - This paper develops a novel instrumented urethral catheter with an array of force sensors for measuring the distributed pressure in a human urethra. The catheter and integrated portions of the force sensors are fabricated by the use of 3D printing using a combination of both soft and hard polymer substrates. Other portions of the force sensors consisting of electrodes and electrolytes are fabricated separately and assembled on top of the 3D-printed catheter to create a soft flexible device. The force sensors use a novel supercapacitive (iontronic) sensing mechanism in which the contact area between a pair of electrodes and a paper-based electrolyte changes in response to force. This provides a highly sensitive measure of force that is immune to parasitic noise from liquids. The developed catheter is tested using a force calibration test rig, a cuff-based pressure application device, an extracted bladder and urethra from a sheep and by dipping inside a beaker of water. The force sensors are found to have a sensitivity of 30–50 nF/N, which is 1000 times larger than that of traditional capacitive force sensors. They exhibit negligible capacitance change when dipped completely in water. The pressure cuff tests and the extracted sheep tissue tests also verify the ability of the sensor array to work reliably in providing distributed force measurements. The developed catheter could help diagnose ailments related to urinary incontinence and inadequate urethral closure pressure.
AB - This paper develops a novel instrumented urethral catheter with an array of force sensors for measuring the distributed pressure in a human urethra. The catheter and integrated portions of the force sensors are fabricated by the use of 3D printing using a combination of both soft and hard polymer substrates. Other portions of the force sensors consisting of electrodes and electrolytes are fabricated separately and assembled on top of the 3D-printed catheter to create a soft flexible device. The force sensors use a novel supercapacitive (iontronic) sensing mechanism in which the contact area between a pair of electrodes and a paper-based electrolyte changes in response to force. This provides a highly sensitive measure of force that is immune to parasitic noise from liquids. The developed catheter is tested using a force calibration test rig, a cuff-based pressure application device, an extracted bladder and urethra from a sheep and by dipping inside a beaker of water. The force sensors are found to have a sensitivity of 30–50 nF/N, which is 1000 times larger than that of traditional capacitive force sensors. They exhibit negligible capacitance change when dipped completely in water. The pressure cuff tests and the extracted sheep tissue tests also verify the ability of the sensor array to work reliably in providing distributed force measurements. The developed catheter could help diagnose ailments related to urinary incontinence and inadequate urethral closure pressure.
KW - Catheter pressure sensors
KW - In vivo force sensors
KW - Instrumented catheter
KW - Iontronic sensors
KW - Parasitic capacitance
KW - Supercapacitive sensors
KW - Urethral sensors
UR - http://www.scopus.com/inward/record.url?scp=85085006538&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85085006538&partnerID=8YFLogxK
U2 - 10.1007/s10439-020-02528-7
DO - 10.1007/s10439-020-02528-7
M3 - Article
C2 - 32377979
AN - SCOPUS:85085006538
SN - 0090-6964
VL - 49
SP - 149
EP - 161
JO - Annals of Biomedical Engineering
JF - Annals of Biomedical Engineering
IS - 1
ER -