An efficient MR phosphorous spectroscopic localization technique for studying ischemic heart

Haiying Liu, Jianyi J Zhang

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

To obtain the spatially resolved 31P spectroscopic image from myocardium during an acute myocardium ischemia at a high signal-to-noise ratio (SNR) in a very limited time window, we have exploited the spatial variation of the radiofrequency (RF) field produced by a single 100p transmit/receive (TR) RF coil along its axis for spatial discrimination. By incrementally lengthening the duration of a square RF excitation pulse, the positional information can be systematically encoded as harmonics of various orders in MR signal. In the in vivo open-chest animal experiment, this RF coil was surgically sutured onto the epicardial surface of the left ventricular (LV) wall over the region perfused by the left anterior descending coronary artery. Using only 17 encoding steps, we have obtained one-dimensional 31P spectroscopic images from both a multiple-layer phosphor phantom and an in vivo LV myocardium. In the animal study, the cardiac gating is used with respiratory synchronization. The MR data were only collected during the end diastole phase of the cardiac cycle (cardiac and respiratory synchronized) with an effective sequence repetition time (TR) of 6 seconds (to ensure the complete relaxation of the phosphorous magnetization). The total acquisition time for a complete experiment is about 10 minutes. Prior to the CSI reconstruction process, the raw data matrix was zero-filled in the spatial dimension. The spatially resolved metabolite map exhibited all the metabolite peaks including creatine phosphate and adenosine triphosphate. At the layer of endocardium, two peaks corresponding to 2,3- diphosphoglycerate, which is contained in the erythrocytes, were clearly seen in the LV wall. Also, the method allows compensation in both volume and coil sensitivity variations for the resulting spectra. All results have demonstrated that it is an efficient nuclear magnetic resonance method capable of obtaining high-quality 31P spectroscopic images with both excellent spatial localization and SNR in the research of cardiac ischemia.

Original languageEnglish (US)
Pages (from-to)892-898
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume10
Issue number5
DOIs
StatePublished - Nov 1999

Keywords

  • Myocardial ischemia
  • Radio frequency
  • Signal-to-noise ratio

Fingerprint Dive into the research topics of 'An efficient MR phosphorous spectroscopic localization technique for studying ischemic heart'. Together they form a unique fingerprint.

Cite this