Skip to main navigation Skip to search Skip to main content

Activities of a nitrofurazone-containing urinary catheter and a silver hydrogel catheter against multidrug-resistant bacteria characteristic of catheter-associated urinary tract infection

Research output: Contribution to journalArticlepeer-review

Abstract

The in vitro inhibitory activity of a nitrofurazone-coated urinary catheter (NFC) against 86 recently obtained susceptible and multidrug- resistant (MDR) clinical isolates of Escherichia coli, Klebsiella pneumoniae, Citrobacter freundii, Staphylococcus aureus, coagulase-negative staphylococci, and Enterococcus faecium, which are species implicated in catheter-associated urinary tract infection and which traditionally have been susceptible to nitrofuran derivatives, was determined using an agar diffusion assay. In a subset of these strains, the activity of the NFC was compared with that of a silver hydrogel urinary catheter (SHC), and the durability of each catheter's inhibitory activity was assessed during serial daily transfers of catheter segments to fresh culture plates. Except for vancomycin-resistant E. faecium, the NFC was active against all isolates tested and showed comparable inhibition zones with susceptible and MDR strains of each species. In contrast, the SHC inhibited only certain staphylococci (P < 0.01 versus the NFC), and among these strains, the SHC produced smaller inhibition zones than did the NFC (P < 0.01). Inhibition was evident for up to 5 days with the NFC, but for only 1 day (if at all) with the SHC (P < 0.01). These data document that, for most genera which traditionally have been susceptible to nitrofuran derivatives, the NFC remains active against contemporary MDR isolates. They also demonstrate that the in vitro antibacterial activity of the NFC is markedly superior to that of the SHC in several respects. Thus, the NFC shows promise for clinical use in the current era of MDR bacteria.

Original languageEnglish (US)
Pages (from-to)2990-2995
Number of pages6
JournalAntimicrobial agents and chemotherapy
Volume43
Issue number12
DOIs
StatePublished - 1999

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Activities of a nitrofurazone-containing urinary catheter and a silver hydrogel catheter against multidrug-resistant bacteria characteristic of catheter-associated urinary tract infection'. Together they form a unique fingerprint.

Cite this