TY - JOUR
T1 - Active heat sink with piezoelectric translational agitators, piezoelectric synthetic jets, and micro pin fin arrays
AU - Yeom, Taiho
AU - Simon, Terrence
AU - Zhang, Min
AU - Yu, Youmin
AU - Cui, Tianhong
N1 - Publisher Copyright:
© 2018
PY - 2018/12
Y1 - 2018/12
N2 - Air-cooled heat sinks are widely used for electronics cooling. Active and passive cooling components can be added to enhance the performance of the air-cooled heat sinks. In this paper, piezoelectric translational agitators and synthetic jets are integrated as active cooling components while micro pin fins are adopted as a passive cooling scheme. The heat transfer performance of the active heat sink system that combines these active and passive cooling components along with a suction fan is experimentally investigated. The piezoelectric translational agitators installed within cooling channels are operating at 222 Hz ∼ 820 Hz with a peak-to-peak displacement of 1.0 mm ∼ 1.4 mm, depending on the attached carbon fiber blade type. The piezoelectric synthetic jet array provides impingement flow into the cooling channels with an inclined configuration, that has been successfully integrated into the system without interference with other components by using a wedge platform. The jet operates at 720 Hz with the jet velocity of up to 39 m/s. Micro pin fins are fabricated onto both surfaces of each heat sink channel walls by a double-sided microfabrication technique. They have diameter, height, and spacing of 500 μm, 250 μm, and 1500 μm, respectively. The experimental results indicate that the micro pin fins are most efficient among the employed active and passive cooling components, reducing thermal resistance up to 38%, compared to plain heat sink performance. The piezoelectric translational agitator reduces system thermal resistance by 22%, compared to the non-agitated condition, at the same through-flow rate. The synthetic jet shows weaker cooling capability in the setting tested, compared to enhancement by the agitator plates or pin fins. The active heat sink with the micro pin fins, agitators, and jets provides a thermal resistance of 0.064 °C/W at 70 CFM (33 L/sec) through-flow of air, about a 48% reduction from that of the non-agitated, plain heat sink under the same operating conditions. The results demonstrate how more effective the active heat sink system is compared to traditional air-cooled heat sinks.
AB - Air-cooled heat sinks are widely used for electronics cooling. Active and passive cooling components can be added to enhance the performance of the air-cooled heat sinks. In this paper, piezoelectric translational agitators and synthetic jets are integrated as active cooling components while micro pin fins are adopted as a passive cooling scheme. The heat transfer performance of the active heat sink system that combines these active and passive cooling components along with a suction fan is experimentally investigated. The piezoelectric translational agitators installed within cooling channels are operating at 222 Hz ∼ 820 Hz with a peak-to-peak displacement of 1.0 mm ∼ 1.4 mm, depending on the attached carbon fiber blade type. The piezoelectric synthetic jet array provides impingement flow into the cooling channels with an inclined configuration, that has been successfully integrated into the system without interference with other components by using a wedge platform. The jet operates at 720 Hz with the jet velocity of up to 39 m/s. Micro pin fins are fabricated onto both surfaces of each heat sink channel walls by a double-sided microfabrication technique. They have diameter, height, and spacing of 500 μm, 250 μm, and 1500 μm, respectively. The experimental results indicate that the micro pin fins are most efficient among the employed active and passive cooling components, reducing thermal resistance up to 38%, compared to plain heat sink performance. The piezoelectric translational agitator reduces system thermal resistance by 22%, compared to the non-agitated condition, at the same through-flow rate. The synthetic jet shows weaker cooling capability in the setting tested, compared to enhancement by the agitator plates or pin fins. The active heat sink with the micro pin fins, agitators, and jets provides a thermal resistance of 0.064 °C/W at 70 CFM (33 L/sec) through-flow of air, about a 48% reduction from that of the non-agitated, plain heat sink under the same operating conditions. The results demonstrate how more effective the active heat sink system is compared to traditional air-cooled heat sinks.
KW - Active heat sink
KW - Actuator
KW - Electronics cooling
KW - Micro pin fin
KW - Piezo fan
KW - Piezoelectric
KW - Surface microstructure
KW - Synthetic jet
KW - Thermal management
UR - http://www.scopus.com/inward/record.url?scp=85050875842&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85050875842&partnerID=8YFLogxK
U2 - 10.1016/j.expthermflusci.2018.07.035
DO - 10.1016/j.expthermflusci.2018.07.035
M3 - Article
AN - SCOPUS:85050875842
SN - 0894-1777
VL - 99
SP - 190
EP - 199
JO - Experimental Thermal and Fluid Science
JF - Experimental Thermal and Fluid Science
ER -