Accelerometer-Based Acoustic Control: Enabling Auscultation on a Black Hawk Helicopter

Garrett Nelson, Rajesh Rajamani

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

During aeromedical patient transport, acoustic noise levels in excess of 90 dB make auscultation with a stethoscope virtually impossible. Existing approaches to address this noise in literature have relied on the use of either passive shielding of the stethoscope sensing element or active noise cancellation (ANC) with the use of additional reference microphone sensors. These solutions have achieved inadequate performance. In this paper, custom instrumented stethoscopes are used to obtain structural vibration and acoustic data from a UH-60 Black Hawk helicopter. The data show that the structural vibrations contribute significantly more to stethoscope signals than air-borne acoustic noise. Therefore, a novel adaptive acoustic control system using a reference accelerometer is pursued. By varying the levels of acoustic and vibrational noise sources in a controlled laboratory environment, the benefits and limitations of microphone or accelerometer-based active noise control are investigated and compared. Experimentally simulating the field acoustic and vibration characteristics of the UH-60 Black Hawk helicopter, the accelerometer-based ANC system is shown to provide significantly superior performance. The accelerometer-based ANC system yields an average 25-dB reduction in ambient noise levels over the entire relevant frequency range, thereby enabling successful auscultation for the first time in this military aircraft environment.

Original languageEnglish (US)
Pages (from-to)994-1003
Number of pages10
JournalIEEE/ASME Transactions on Mechatronics
Volume22
Issue number2
DOIs
StatePublished - Apr 1 2017

Fingerprint

Accelerometers
Helicopters
Acoustics
Acoustic noise
Microphones
Vibrations (mechanical)
Active noise control
Military aircraft
Acoustic fields
Shielding
Control systems
Sensors
Air

Keywords

  • Accelerometer
  • active noise cancellation (ANC)
  • auscultation
  • medical signal detection
  • stethoscope

Cite this

Accelerometer-Based Acoustic Control : Enabling Auscultation on a Black Hawk Helicopter. / Nelson, Garrett; Rajamani, Rajesh.

In: IEEE/ASME Transactions on Mechatronics, Vol. 22, No. 2, 01.04.2017, p. 994-1003.

Research output: Contribution to journalArticle

@article{c97cc2db912b4c159f3531246fe0bc7f,
title = "Accelerometer-Based Acoustic Control: Enabling Auscultation on a Black Hawk Helicopter",
abstract = "During aeromedical patient transport, acoustic noise levels in excess of 90 dB make auscultation with a stethoscope virtually impossible. Existing approaches to address this noise in literature have relied on the use of either passive shielding of the stethoscope sensing element or active noise cancellation (ANC) with the use of additional reference microphone sensors. These solutions have achieved inadequate performance. In this paper, custom instrumented stethoscopes are used to obtain structural vibration and acoustic data from a UH-60 Black Hawk helicopter. The data show that the structural vibrations contribute significantly more to stethoscope signals than air-borne acoustic noise. Therefore, a novel adaptive acoustic control system using a reference accelerometer is pursued. By varying the levels of acoustic and vibrational noise sources in a controlled laboratory environment, the benefits and limitations of microphone or accelerometer-based active noise control are investigated and compared. Experimentally simulating the field acoustic and vibration characteristics of the UH-60 Black Hawk helicopter, the accelerometer-based ANC system is shown to provide significantly superior performance. The accelerometer-based ANC system yields an average 25-dB reduction in ambient noise levels over the entire relevant frequency range, thereby enabling successful auscultation for the first time in this military aircraft environment.",
keywords = "Accelerometer, active noise cancellation (ANC), auscultation, medical signal detection, stethoscope",
author = "Garrett Nelson and Rajesh Rajamani",
year = "2017",
month = "4",
day = "1",
doi = "10.1109/TMECH.2016.2603444",
language = "English (US)",
volume = "22",
pages = "994--1003",
journal = "IEEE/ASME Transactions on Mechatronics",
issn = "1083-4435",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

TY - JOUR

T1 - Accelerometer-Based Acoustic Control

T2 - Enabling Auscultation on a Black Hawk Helicopter

AU - Nelson, Garrett

AU - Rajamani, Rajesh

PY - 2017/4/1

Y1 - 2017/4/1

N2 - During aeromedical patient transport, acoustic noise levels in excess of 90 dB make auscultation with a stethoscope virtually impossible. Existing approaches to address this noise in literature have relied on the use of either passive shielding of the stethoscope sensing element or active noise cancellation (ANC) with the use of additional reference microphone sensors. These solutions have achieved inadequate performance. In this paper, custom instrumented stethoscopes are used to obtain structural vibration and acoustic data from a UH-60 Black Hawk helicopter. The data show that the structural vibrations contribute significantly more to stethoscope signals than air-borne acoustic noise. Therefore, a novel adaptive acoustic control system using a reference accelerometer is pursued. By varying the levels of acoustic and vibrational noise sources in a controlled laboratory environment, the benefits and limitations of microphone or accelerometer-based active noise control are investigated and compared. Experimentally simulating the field acoustic and vibration characteristics of the UH-60 Black Hawk helicopter, the accelerometer-based ANC system is shown to provide significantly superior performance. The accelerometer-based ANC system yields an average 25-dB reduction in ambient noise levels over the entire relevant frequency range, thereby enabling successful auscultation for the first time in this military aircraft environment.

AB - During aeromedical patient transport, acoustic noise levels in excess of 90 dB make auscultation with a stethoscope virtually impossible. Existing approaches to address this noise in literature have relied on the use of either passive shielding of the stethoscope sensing element or active noise cancellation (ANC) with the use of additional reference microphone sensors. These solutions have achieved inadequate performance. In this paper, custom instrumented stethoscopes are used to obtain structural vibration and acoustic data from a UH-60 Black Hawk helicopter. The data show that the structural vibrations contribute significantly more to stethoscope signals than air-borne acoustic noise. Therefore, a novel adaptive acoustic control system using a reference accelerometer is pursued. By varying the levels of acoustic and vibrational noise sources in a controlled laboratory environment, the benefits and limitations of microphone or accelerometer-based active noise control are investigated and compared. Experimentally simulating the field acoustic and vibration characteristics of the UH-60 Black Hawk helicopter, the accelerometer-based ANC system is shown to provide significantly superior performance. The accelerometer-based ANC system yields an average 25-dB reduction in ambient noise levels over the entire relevant frequency range, thereby enabling successful auscultation for the first time in this military aircraft environment.

KW - Accelerometer

KW - active noise cancellation (ANC)

KW - auscultation

KW - medical signal detection

KW - stethoscope

UR - http://www.scopus.com/inward/record.url?scp=85027414968&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027414968&partnerID=8YFLogxK

U2 - 10.1109/TMECH.2016.2603444

DO - 10.1109/TMECH.2016.2603444

M3 - Article

AN - SCOPUS:85027414968

VL - 22

SP - 994

EP - 1003

JO - IEEE/ASME Transactions on Mechatronics

JF - IEEE/ASME Transactions on Mechatronics

SN - 1083-4435

IS - 2