TY - JOUR
T1 - A self-tuned graph-based framework for localization and grading prostate cancer lesions
T2 - An initial evaluation based on multiparametric magnetic resonance imaging
AU - Chen, Weifu
AU - Lin, Mingquan
AU - Gibson, Eli
AU - Bastian-Jordan, Matthew
AU - Cool, Derek W.
AU - Kassam, Zahra
AU - Liang, Huageng
AU - Feng, Guocan
AU - Ward, Aaron D.
AU - Chiu, Bernard
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/5/1
Y1 - 2018/5/1
N2 - Multiparametric magnetic resonance imaging (mpMRI) has been established as the state-of-the-art examination for the detection and localization of prostate cancer lesions. Prostate Imaging-Reporting and Data System (PI-RADS) has been established as a scheme to standardize the reporting of mpMRI findings. Although lesion delineation and PI-RADS ratings could be performed manually, human delineation and ratings are subjective and time-consuming. In this article, we developed and validated a self-tuned graph-based model for PI-RADS rating prediction. 34 features were obtained at the pixel level from T2-weighted (T2W), apparent diffusion coefficient (ADC) and dynamic contrast enhanced (DCE) images, from which PI-RADS scores were predicted. Two major innovations were involved in this self-tuned graph-based model. First, graph-based approaches are sensitive to the choice of the edge weight. The proposed model tuned the edge weights automatically based on the structure of the data, thereby obviating empirical edge weight selection. Second, the feature weights were tuned automatically to give heavier weights to features important for PI-RADS rating estimation. The proposed framework was evaluated for its lesion localization performance in mpMRI datasets of 12 patients. In the evaluation, the PI-RADS score distribution map generated by the algorithm and from the observers’ ratings were binarized by thresholds of 3 and 4. The sensitivity, specificity and accuracy obtained in these two threshold settings ranged from 65 to 77%, 86 to 93% and 85 to 88% respectively, which are comparable to results obtained in previous studies in which non-clinical T2 maps were available. The proposed algorithm took 10s to estimate the PI-RADS score distribution in an axial image. The efficiency achievable suggests that this technique can be developed into a prostate MR analysis system suitable for clinical use after a thorough validation involving more patients.
AB - Multiparametric magnetic resonance imaging (mpMRI) has been established as the state-of-the-art examination for the detection and localization of prostate cancer lesions. Prostate Imaging-Reporting and Data System (PI-RADS) has been established as a scheme to standardize the reporting of mpMRI findings. Although lesion delineation and PI-RADS ratings could be performed manually, human delineation and ratings are subjective and time-consuming. In this article, we developed and validated a self-tuned graph-based model for PI-RADS rating prediction. 34 features were obtained at the pixel level from T2-weighted (T2W), apparent diffusion coefficient (ADC) and dynamic contrast enhanced (DCE) images, from which PI-RADS scores were predicted. Two major innovations were involved in this self-tuned graph-based model. First, graph-based approaches are sensitive to the choice of the edge weight. The proposed model tuned the edge weights automatically based on the structure of the data, thereby obviating empirical edge weight selection. Second, the feature weights were tuned automatically to give heavier weights to features important for PI-RADS rating estimation. The proposed framework was evaluated for its lesion localization performance in mpMRI datasets of 12 patients. In the evaluation, the PI-RADS score distribution map generated by the algorithm and from the observers’ ratings were binarized by thresholds of 3 and 4. The sensitivity, specificity and accuracy obtained in these two threshold settings ranged from 65 to 77%, 86 to 93% and 85 to 88% respectively, which are comparable to results obtained in previous studies in which non-clinical T2 maps were available. The proposed algorithm took 10s to estimate the PI-RADS score distribution in an axial image. The efficiency achievable suggests that this technique can be developed into a prostate MR analysis system suitable for clinical use after a thorough validation involving more patients.
KW - Laplacian regularized regression model
KW - Multiparametric MRI (mpMRI)
KW - Multiple kernel learning
KW - Prostate cancer
KW - Prostate Imaging and Reporting Data System (PI-RADS)
UR - http://www.scopus.com/inward/record.url?scp=85045111152&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85045111152&partnerID=8YFLogxK
U2 - 10.1016/j.compbiomed.2018.03.017
DO - 10.1016/j.compbiomed.2018.03.017
M3 - Article
C2 - 29653354
AN - SCOPUS:85045111152
SN - 0010-4825
VL - 96
SP - 252
EP - 265
JO - Computers in Biology and Medicine
JF - Computers in Biology and Medicine
ER -