T1 - A multicenter, randomized trial comparing an active can implantable defibrillator with a passive can system
AU - Haffajee, C.
AU - Martin, D.
AU - Bhandari, A.
AU - Bardy, G. H.
AU - DeSouza, C.
AU - Kuehlkamp, V.
AU - Church, T.
PY - 1997
Y1 - 1997
N2 - Replacing one defibrillation electrode lead by the defibrillator can may simplify implantation of the ICD. In this multicenter study, 304 patients were randomized to receive either the biphasic active can (AC) (model 7219C system, Medtronic, Inc.) or the passive can (PC) (model 7219D system). The AC and PC systems were compared with respect to their ability to meet the implant defibrillation criterion and to defibrillate VF, and to DFTs, implant time, patient adverse events, and survival rates. A higher percentage fulfilled the implant defibrillation criterion on the first configuration with the AC (86.3% vs 75.9% for PC; P = 0.023), and the first shock success for terminating induced VF was 94% for AC compared to 80% for PC (P = 0.026). DFTs were significantly lower (10.9 vs 12.7 J; P = 0.031), and implant time was significantly shorter for the A C patients (99.2 vs 112.0 min; P = 0.002). The two groups showed no significant differences in 3-month adverse event rates, 3-month survival, and hospital stay.
AB - Replacing one defibrillation electrode lead by the defibrillator can may simplify implantation of the ICD. In this multicenter study, 304 patients were randomized to receive either the biphasic active can (AC) (model 7219C system, Medtronic, Inc.) or the passive can (PC) (model 7219D system). The AC and PC systems were compared with respect to their ability to meet the implant defibrillation criterion and to defibrillate VF, and to DFTs, implant time, patient adverse events, and survival rates. A higher percentage fulfilled the implant defibrillation criterion on the first configuration with the AC (86.3% vs 75.9% for PC; P = 0.023), and the first shock success for terminating induced VF was 94% for AC compared to 80% for PC (P = 0.026). DFTs were significantly lower (10.9 vs 12.7 J; P = 0.031), and implant time was significantly shorter for the A C patients (99.2 vs 112.0 min; P = 0.002). The two groups showed no significant differences in 3-month adverse event rates, 3-month survival, and hospital stay.
KW - active can defibrillator
KW - implantable cardioverter defibrillators
UR - http://www.scopus.com/inward/record.url?scp=0031018040&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031018040&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.1997.tb04846.x
DO - 10.1111/j.1540-8159.1997.tb04846.x
M3 - Article
C2 - 9121993
AN - SCOPUS:0031018040
SN - 0147-8389
VL - 20
SP - 215
EP - 219
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 1 SUPPL.
ER -